IBM ServeRAID User Reference page 170

Hide thumbs Also See for ServeRAID:
Table of Contents

Advertisement

BCS
ECS
Explanation
07
0C
Online/rebuild drives are not responding,
and a drive was found at the incorrect SCSI
ID.
07
1C
Online/rebuild and hot spare/standby
hot-spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
07
2C
Online/rebuild and ready/standby drives are
not responding, and a drive was found at
the incorrect SCSI ID.
07
3C
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, and a drive was found at the
incorrect SCSI ID.
07
4C
Online/rebuild drives are not responding,
and a drive was found at the incorrect SCSI
ID, and unidentified drives were found.
07
5C
Online/rebuild and hot spare/standby
hot-spare drives are not responding, a drive
was found at the incorrect SCSI ID, and
unidentified drives were found.
07
6C
Online/rebuild and ready/standby drives are
not responding, a drive was found at the
incorrect SCSI ID, and unidentified drives
were found.
07
7C
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, a drive was found at the
incorrect SCSI ID, and unidentified drives
were found.
07
18
Online/rebuild and hot spare/standby
hot-spare drives are not responding.
07
28
Online/rebuild and ready/standby drives are
not responding.
07
38
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding.
07
48
Online/rebuild drives are not responding,
and unidentified drives were found.
07
58
Online/rebuild and hot spare/standby
hot-spare drives are not responding, and
unidentified drives were found.
07
68
Online/rebuild and ready/standby drives are
not responding, and unidentified drives were
found.
07
78
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, and unidentified drives were
found.
09
00
No error occurred.
154
IBM ServeRAID: User's Reference, Version 5.10
Action
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
Note: Pressing F4 might not correct the
problem. If you do not return the drives and
cables to the previous configuration, the
message might return.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
3. To modify the configuration and accept the
rearrangement of the physical drives, press
F6.
To exit without making changes, press F10.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
To exit without making changes, press F10.
No action is required. Press F10 to exit without
making any changes.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ServeRAID and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Serveraid-4hServeraid-4mxServeraid-4lxServeraid-5i

Table of Contents