IBM ServeRAID User Reference page 169

Hide thumbs Also See for ServeRAID:
Table of Contents

Advertisement

BCS
ECS
Explanation
03
88
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild drives are not responding.
03
98
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild and hot spare/standby
hot-spare drives are not responding.
03
A8
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild and ready/standby drives are
not responding.
03
B8
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild, hot spare/standby hot-spare,
and ready/standby drives are not
responding.
03
C8
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild drives are not responding and
unidentified drives were found.
03
D8
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild and hot spare/standby
hot-spare drives are not responding and
unidentified drives were found.
03
E8
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild and ready/standby drives are
not responding and unidentified drives were
found.
03
F8
A drive was imported from another server
and it has a valid configuration, and the
online/rebuild, hot spare/standby hot-spare,
and ready/standby drives are not responding
and unidentified drives were found.
07
00
The specified drive is not responding.
07
08
The specified drives are not responding.
Action
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives that
were switched and press F4 to retry.
Attention:
Completing step 2 might result in
a loss of the original configuration and data on
the drives.
2. To accept the new configuration from the
physical drives, press F7.
3. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
To exit without making changes, press F10.
To correct the problem:
1. If the specified physical drive or drives are in
an external enclosure, verify that the
enclosure is turned on. If the enclosure is
turned off, turn on the power and press F4 to
retry.
2. Download and install the latest version of IBM
ServeRAID software. See Chapter 16,
"Obtaining ServeRAID updates" on page 141
for more information.
3. Replace the failed physical drive or drives.
Chapter 18. Solving ServeRAID problems
153