BCS
ECS
Explanation
01
08
No configuration was found in drives, or the
online/rebuild drives are not responding.
01
18
No configuration was found in drives, or the
online/rebuild and hot spare/standby
hot-spare drives are not responding.
01
28
No configuration was found in drives, or the
online/rebuild and ready/standby drives are
not responding.
01
38
No configuration was found in drives, or the
online/rebuild, hot spare/standby hot-spare,
and ready/standby drives are not
responding.
01
48
No configuration was found in drives, or the
online/rebuild drives are not responding and
unidentified drives were found.
01
58
No configuration was found in drives, or the
online/rebuild and hot spare/standby
hot-spare drives are not responding and
unidentified drives were found.
01
68
No configuration was found in drives, or the
online/rebuild and ready/standby drives are
not responding and unidentified drives were
found.
01
78
No configuration was found in drives, or the
online/rebuild, hot spare/standby hot-spare,
and ready/standby drives are not responding
and unidentified drives were found.
152
IBM ServeRAID: User's Reference, Version 5.10
Action
To correct the problem:
1. If the controller is connected to an enclosure,
verify that the enclosure is on. If the enclosure
is off, turn on the power and press F4 to retry.
2. Verify that all the physical drives are present.
If any drives are missing, replace the drives
and press F4 to retry.
3. Verify that all the physical drives are
connected to the controller correctly. If any
drives are unconnected, connect the drives
and press F4 to retry.
4. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
5. If you have intentionally switched physical
drives that are connected to this controller,
press F7 to import the configuration from the
drives and account for the drive
rearrangement.
To exit without making changes, press F10.