IBM ServeRAID User Reference page 97

Hide thumbs Also See for ServeRAID:
Table of Contents

Advertisement

Function
What it does
flashcopy
Use this function to merge logical-drive
import
information from physical drives when they
are added to an existing server
configuration.
Notes:
1. The stripe-unit size of the logical drives
being imported must be the same as
the stripe-unit size of the logical drives
on the new controller.
2. The number of physical drives you add
must be equal to the number of
physical drives that were in the logical
drive defined originally.
3. The physical drives must be added
while the server is on.
4. When a logical drive is imported, all
partitions from that logical drive are
also imported automatically. You cannot
import a single partition selectively.
5. You must manually assign drive letters
after the import is completed.
6. The FlashCopy import function is not
available in a cluster configuration.
Command
IPSSEND FLASHCOPY controller IMPORT ALL/n
where:
v controller is the ServeRAID controller number (1–12)
v ALL specifies that all logical drives are to be imported
v n is the logical drive number (1–8) for the specific
drive you want to import
Chapter 8. Installing and using the IPSSEND command-line program