ProMinent Sigma 1 Supplementary Operating Instructions page 41

Pumps with hygienic pump head
Table of Contents

Advertisement

S3BA with hygienic pump head at 60
Hz operation
Type
Minimum pump capacity at maximum back pressure
bar
120145
10
120190
10
120270
10
070410
7
070580
7
040830
4
Type
Maximum
stroke rate
Strokes/min
120145
86
120190
124
120270
173
070410
86
070580
124
040830
173
psi
l/h
145
178
145
257
145
358
102
447
102
657
58
961
Priming lift
Suction lift
mbar
mbar
180
500
180
500
180
500
190
400
190
400
190
400
Technical data
gph
ml/stroke
46.9
34.4
67.8
34.6
94.4
34.4
117.9
86.7
173.3
88.3
253.5
92.6
Max. permissible
Connector size
priming pressure
on the suction side
DN
25
25
25
32
32
32
41