Chapter 16
16.3.11.2 Detailed Discussions of Bit 5
When "Detect with the new method" is selected, tone is detected for 3.5 seconds before call origination in order to discriminate between dial tone and voice. If dial
tone is detected and the time since line seizure is 3.5 seconds or longer, call origination takes place immediately. If the time since line seizure is less than 3.5 seconds,
call origination takes place after waiting for 1 second. (If the time since line seizure reaches 3.5 seconds during the 1-second waiting period, call origination takes
place immediately. By default, "Detect with a new method" is assigned for this SW.
16.3.12 SSSW-SW33
16.3.12.1 List of Functions
Bit
0
1
2
3
4
5
6
7
16.3.12.2 Detailed Discussions of Bit 0
Use it to specify whether B4 paper (Print) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
16.3.12.3 Detailed Discussions of Bit 1
Use it to specific whether to indicate the machine serial No. on the Counter Check screen, appearing when the Counter key is pressed.
If 'yes' is selected, the serial No. will be indicated.
If 'no' is selected, on the other hand, the serial No. will not be indicated.
16.3.12.4 Detailed Discussions of Bit 2
Use it to specify whether B4 paper (Scan) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
16.4 Menu Switch Settings (MENU)
16.4.1 Menu Switch Composition
No.
005
006
007
008
009
010
16-16
Function
count B4 (Print) as large size *1
indicate serial No. on counter check screen *1
count B4 (Scan) as large size *1
Not used
Not used
Not used
Not used
Not used
*1: if equipped with soft couter functions
Function
Range of settings
NL equalizer
1: ON, 0: OFF
telephone line monitor
0:DIAL, 1:SERVICEMAN1, 2:SERVICEMAN2, 3:OFF
transmission level (ATT)
from 0 to 15 (ex: 15= -15 dBm)
V.34 modulation speed upper
0:3429, 1:3200, 2:3000, 3:2800, 4:2743, 5:2400
limit
V34 data speed upper limit
0:33.6 kbps, 1:31.2 kbps, 2:28.8 kbps, 3:26.4 kbps, 4:24.0 kbps,
5:21.6 kbps, 6:19.2 kbps, 7:16.8 kbps, 8:14.4 kbps, 9:12.0 kbps,
10:9.6 kbps, 11:7.2 kbps, 12:4.8 kbps, 13:2.4 kbps
Frequency of pseudoring signal
0:50 Hz, 1:25 Hz, 2:17 Hz