10.2 ECD SMARTDRY™ HUMIDITY AND TEMPERATURE SENSOR
This sensor is a highly accurate environmental sensors. Exposing the sensor to the following can cause drift of
the humidity reading – irreversibly in most cases. The list below are examples and do not represent a com-
plete list of possible harmful substances, but are the most common used in electronic manufacturing.
Do not allow the sensor to be exposed to:
Solvents or other organic compounds including: Ketenes, Acetone, Ethanol, Isopropyl Alcohol, Tolu-
ene, etc.
Acids and bases including: HCl, H2SO4, HNO3, NH3 etc.
Ozone in high concentration or H2O2
Cleaning agents or strong air blasts from an air-gun.
Please note that such chemicals are contained in uncured epoxies, glues, adhesives, etc. and out-
gas during baking and curing. Do not use the ECD SmartDRY™ Cabinet as a curing chamber for
these processes. These chemicals are also added as plasticizers in plastics, used for packaging ma-
terials, and may also out gas for some time. Only allow well cured approved Moisture Barrier Bag
to be use in the Cabinet.