Siegenia AERO AEROMAT VT WRG 1100 Original Operating Instructions

Siegenia AERO AEROMAT VT WRG 1100 Original Operating Instructions

Hide thumbs Also See for AERO AEROMAT VT WRG 1100:

Advertisement

Quick Links

ORIGINAL OPERATING
INSTRUCTIONS
AERO
AEROMAT VT WRG 1100
Sound absorbing ventilator.
Window systems
Door systems
Comfort systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AERO AEROMAT VT WRG 1100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Siegenia AERO AEROMAT VT WRG 1100

  • Page 1 ORIGINAL OPERATING INSTRUCTIONS AERO AEROMAT VT WRG 1100 Sound absorbing ventilator. Window systems Door systems Comfort systems...
  • Page 2: Table Of Contents

    General faults ..........19 9.2. Ventilation.with.blower ....... 10 15.2 Fault messages ..........19 9.3. Ventilation.in.automatic.mode ....11 15.3. SIEGENIA.Comfort.app ........ 19 9.4. Condensate.and.frost.protection.control ..11 TECHNICAL SPECIFICATIONS ....20 MEMBRANE KEY AND LED DISPLAY ..11 16.1 Data table ............ 20 16.2 Dimensions ..........
  • Page 3: Target Group Of This Documentation

    Weather.grille:.HW-g.(concealed.installation.in. gas.systems.of.solid.fuel.heating.units.must.be.able. the.wall);.installation.position:.horizontal to.be.shut.off. • Only. o perate. a nd/or. s tore. t he. A EROMAT VT WRG 1100 at.temperatures.between.‒.15.°C.and.+40.°C. • Use.the.AEROMAT VT WRG 1100.only.with.genuine. Weather.grille:.CW;.installation.position:.horizontal accessories.from.SIEGENIA. • Use.the.AEROMAT VT WRG 1100.only.when.it.is.in.a. technically.sound.condition. Weather.grille:.HS;.installation.position:.vertical • Do.not.modify.the.unit's.components.in.any.way. • Ensure.that.the.ventilation.openings.are.kept.free. and.are.not.blocked.by.other.equipment,.furniture. Weather.grille:.CS;.installation.position:.vertical or.objects.
  • Page 4: Safety Notes

    – Should.a.solid.object.or.any.liquid.get.inside.the. steps.and.work.overhead.or.at.certain.heights. unit,.stop.operation.immediately.and.disconnect. the.AEROMAT VT WRG 1100.from.the.electricity. • Electrically.operated.unit..Risk.of.fatal.injury.from. grid..Check.whether.the. electric.shock.or.fire..To.prevent.personal.injury. AEROMAT VT WRG 1100.has.become.damaged.. or.damage.to.property,.always.comply.with.the. Have.the.unit.repaired.by.a.specialist,.if. following.instructions: necessary. – work.on.a.230.V.AC.mains.power.supply.may. • Danger.due.to.third.party.attacks.on.SIEGENIA.WIFI. only.be.performed.by.a.qualified.electrician. devices!.Please.observe.the.following.notes.to. protect.your.system.against.attacks.by.third.parties: – If.the.mains.connection.cable.for.the.unit.is. damaged,.it.must.be.replaced.by.SIEGENIA,.the. – every.SIEGENIA.WIFI.device.is.protected.by. company's.customer.service.department,.or. two.passwords.(user.and.administrator)..It.is. similarly.qualified.personnel.in.order.to.prevent. essential.that.you.change.these.passwords.after. personal.injury.or.damage.to.property. the.initial.setup..Do.not.leave.in.the.default. setting.
  • Page 5: General Notes

    Original.operating.instructions ● ● Quick.start.instructions.SIEGENIA.Comfort.app. – ● The quick start instructions for the SIEGENIA Comfort app are located behind the front panel (To open the front panel, see page 16). Equipment AEROMAT VT WRG 1100 AEROMAT VT WRG 1100 name smart Operation.via.membrane.key...
  • Page 6: Installation

    Original operating instructions AERO AEROMAT VT WRG 1100 Installation 7.1 Installation options 7.2 Installation requirements Installation.in.the. • The.position.from.which.the.outdoor.air.is.drawn. wall in.must.be.selected.in.such.way.that.any.nearby. emission.sources.have.as.little.impact.as.possible.on. the.quality.of.the.air.being.drawn.in. AEROMAT VT • The.maximum.permissible.area.load.is.1,000.kg.per. running.metre.of.ventilator.length. Concealed. 7.3 Additional requirements for installation.in.the. wall.with.wall.duct AEROMAT VT WRG 1100 smart • The.AEROMAT VT WRG 1100.smart.should.be. AEROMAT VT installed.to.be.as.free.from.interference.as.possible..
  • Page 7: Installation.sequence

    Original operating instructions AERO AEROMAT VT WRG 1100 7.4 Installation sequence 4. Install.the.AEROMAT VT WRG 1100 in its intended installation.position.and.seal.it.in.accordance.with. 1. Remove.the.AEROMAT VT WRG 1100.carefully.from. the.installation.directives.applicable.on.site. the.packaging.and.do.not.place.it.on.the.weather. grille.or.front.panel..We.recommend.storing.the.unit. 5. Check.AEROMAT VT WRG 1100.for.cleanliness. on.a.soft.surface.(e.g..cardboard.or.sheet).during. prior.to.starting.it.up..Clean.if.necessary.(see. installation. "maintenance.and.care".on.page.15). Only.drill.in.through-holes.for.wall.plugs.and. 2. Close.the.sliders.on.the.front.to.prevent.dirt.(e.g.. screws.in.the.area.indicated.(see.marker.tape).
  • Page 8: Extension.parts

    Original operating instructions AERO AEROMAT VT WRG 1100 7.5 Extension parts 7.6 Z profile Screw.on.the.mounting.angle.in.the.area.indicated. First,.fix.the.Z.profile.(optional).to.the.weather.grille. (marker.tape).or.fasten.it.to.the.casing.profiles. using.double-sided.adhesive.tape,.then.drill.and.rivet.it. with.a.rivet..We.recommend.that.you.use.SIEGENIA. aluminium.mounting.angles. AEROMAT VT WRG 1100.with.weather.grille.CW AEROMAT VT WRG 1100.with.weather.grille.HW Dimension Meaning Assembly.area.for.bracket Screw.and.drilling.area.(e.g..for.wall. plugs.or.mounting.screws) Overall.depth Bracket.20.x.20.x.2.(optional) Z.profile.(optional) Stop.profile.(optional) 8/24 03.2022 H47.FENS039EN-05...
  • Page 9: Mains Supply

    Original operating instructions AERO AEROMAT VT WRG 1100 Mains supply 8.1 External switch connection WARNING If.the.AEROMAT VT WRG 1100.is.connected.directly. Exposed.electrical.components to.the.230.V.AC.mains.power.supply,.the.customer. Risk of fatal injury from electric shock or fire must install a mains isolator. • work.on.a.230.V.AC.mains.power.supply.may.only.be. performed.by.a.qualified.electrician. • All.work.on.the.230.V.AC.mains.power.supply.must.be. carried.out.in.compliance.with.the.current.German.VDE.
  • Page 10: Unit Function

    Original operating instructions AERO AEROMAT VT WRG 1100 Unit function 9.1 Ventilation without blower 9.2 Ventilation with blower • The.room.is.ventilated.through.air.pressure. • The.outside.air.(2).is.drawn.in.and.enters.the.room. compensation.between.the.indoor.and.outdoor. as.filtered.supply.air.(10). air.(pressure.differential)..As.this.happens,.the.air. normally.flows.into.the.room.from.outside. • The.exhaust.air.(11).is.drawn.in.and.is.released.into. the.atmosphere.as.exhaust.air.(1). • The.air.flow.into.the.room.varies.as.the.wind. pressure.changes.with.the.weather. • Both.streams.of.air.are.drawn.through.the.heat. exchanger.(4)..Here,.particularly.during.cold.times. of.the.year,.the.outside.air.is.pre-heated.by.the. warm.exhaust.air.before.it.enters.the.room.as. supply.air. Item value Item value Exhaust.air...
  • Page 11: Ventilation.in.automatic.mode

    Original operating instructions AERO AEROMAT VT WRG 1100 9.3 Ventilation in automatic mode 9.4 Condensate and frost protection control • The.blower.levels.1.and.2.are.controlled.in. • The.condensate.and.frost.protection.control.serves. automatic.mode...The.necessary.blower.level.is. the.device.protection.and.secures.the.functioning. dependent.on.the.temperature.and.air.humidity. of.the.device.even.in.case.of.lower.outside. as.well.as.optionally.on.the.CO .value.and.on.the. temperatures. TWOC.value..The.least.favourable.value.is.the. significant.value. • The.supply.air.volume.flow.is.reduced.at.an.outside. temperature.of.+5.°C. • The.blowers.are.not.switched.off,.but.continue.to. run at a minimum level. •...
  • Page 12: Commissioning

    • For.units.with.air.quality.sensors,.a.one-off. 1. Air.the.room.thoroughly.for.10.min. calibration.of.the.sensor.is.performed.during. the.commissioning..The.sensor.adapts.to.the. 2. Switch..AEROMAT VT WRG 1100.to.the.electricity. environment. grid. • The.room.temperature.must.be.between.5.°C.and. 3. The.exhaust.air.sensors.automatically.start.a. 40.°C. warming-up.phase.(duration.approx..5.min.): LED.1+2.flash.red • The.calibration.lasts.24.hours. membrane.key.flashes.blue • The.automatic.mode.already.functions.during.the. calibration. 4. The.calibration.starts.automatically. • AEROMAT VT WRG 1100.smart:.the.air.quality. is.already.displayed.during.the.calibration.in.the. SIEGENIA.Comfort.app. • The.accuracy.of.the.sensor.rises.with.the.continuing. duration.of.the.calibration. 12/24 03.2022 H47.FENS039EN-05...
  • Page 13: Operation

    Original operating instructions AERO AEROMAT VT WRG 1100 12 Operation 12.1 Ventilation without blower 12.3 Adjustment of the blower level using the membrane key • By.pressing.the.membrane.key.several.times,.you. can.activate.the.required.blower.levels.(relaying). • After.a.power.failure,.the.device.switches.to.the.last. level to be used. Switching sequence Blower.level.0 Blower.level.1 Blower.level.2 1. Open.sliders. Automatic Power level 12.2 Ventilation with blower...
  • Page 14: Adjustment Of The Blower Level Using The External Switch

    Original operating instructions AERO AEROMAT VT WRG 1100 12.4 Adjustment of the blower level using the 3-stage rotary switch + changeover switch external switch Blower.level.0 Blower.level.1 Blower.level.2 • You.can.activate.the.required.blower.levels.directly. Manuell Manuell Manuell by.pressing.the.external.switch.(without.relaying). • After.a.power.failure,.the.device.switches.to.the.last. Auto Auto Auto level to be used. •...
  • Page 15: Operation Via Smartphone Or Tablet (Aeromat Vt Wrg 1100 Smart Only)

    12.5 Operation via smartphone or tablet 12.5.2 Unit functions in the app (AEROMAT VT WRG 1100 smart only) Blower performance The.AEROMAT VT WRG 1100.smart.can.be.controlled. • The.blower.performance.can.be.set.manually. by.a.tablet.or.smartphone.and.offers.additional.device. functions.via.the.SIEGENIA.Comfort.app. • On.application.of.the.automatic.mode,.the.manually. adjusted.blower.performance.is.overridden. Automatic mode • For.information.on.the.automatic.mode,.see.page. Warning (replace filter) • As.soon.as.a.filter.replacement.is.required,.this.will.
  • Page 16: Maintenance.intervals

    13.3 Removing the front panel Cleaning the insect screen The.figure.below.shows.the.opening.direction.for.a. AEROMAT VT WRG 1100.that.has.been.installed. Clean.the.insect.screen.every.6.months. horizontally. Changing the filter Replace.filter.every.12.months.or.when.the.filter. change.indicator.lights.up. Filters.must.be.replaced,.not.cleaned..Only.use. genuine.filters.from.SIEGENIA..You.can.purchase. replacement.filters.from.SIEGENIA or from specialist.retailers. Cleaning the air passages and heat exchanger Check.and.clean.air.passages.and.heat.exchanger.every. 12.months. Condensation.does.not.generally.develop..If.the. surface.of.the.heat.exchanger.becomes.wet.for.a. short.period,.as.can.happen.in.damp.locations,.for. example,.the.moisture.will.dissipate.quickly.with. the.outgoing.air. 1. Open.the.locking.bolt.
  • Page 17: Replacing.the.exhaust.air.filter

    Original operating instructions AERO AEROMAT VT WRG 1100 13.4 Replacing the exhaust air filter 13.5 Changing the supply air filter 1. Remove.the.front.panel.(see.page.16). 1. Remove.the.front.panel.(see.16). 2. Remove.the.retention.springs. 2. Remove.the.exhaust.air.filter.(see.17). 3. Remove.the.exhaust.air.filter.and.dispose.of.it.as. 3. Turn.the.supporting.piece.90°. household.waste. 4. Remove.the.cover. 4. Insert.a.new.exhaust.air.filter. 5. Reassemble.the.AEROMAT VT WRG 1100.in.the. reverse order.
  • Page 18: Cleaning.the.heat.exchanger

    Original operating instructions AERO AEROMAT VT WRG 1100 13.6 Cleaning the heat exchanger Caution!.Sharp.edges.on.the.casing.profile.-.Wear. 5. Remove.the.foam.padding. protective.gloves! 6. Remove.the.heat.exchanger.and.clean.it.thoroughly. under running water. 1. Remove.the.front.panel.(see.page.16). 7. Leave.the.heat.exchanger.to.dry.completely. 2. Remove.the.exhaust.air.filter.(see.page.17). 8. Insert.the.cleaned.heat.exchanger.so.that.it.is. 3. Turn.the.supporting.piece.90°. sealed.on.all.sides.in.the.casing. 4. Remove.the.cover. 9. Reassemble.AEROMAT.VT.WRG.1100.in.the.reverse. order. 14 Accessories name Contents Material number...
  • Page 19: Troubleshooting

    3..The.AEROMAT VT WRG 1100 smart.has.been. reset.to.the.factory.settings. 15.2 Fault messages Membrane key / LED Reason Solution membrane key Filter soiled. Change.the.filter.(see.page.21). flashes.blue As.soon.as.the.outside.temperature. The.frost.protection.control.is. increases.above.-10.°C.again,.the. LED.2.flashes.red active. device.switches.to.the.last.level.to.be. used. LED.1+2.flash.red. Sensor.is.defective. Contact.specialist.company. alternately 15.3 SIEGENIA Comfort app You.will.find.detailed.information.on.operation. and.the.rectification.of.malfunctions.in.the. SIEGENIA.FAQ.Portal:.siegenia.com/service/portal#/faq H47.FENS039EN-05 03.2022 19/24...
  • Page 20: Technical Specifications

    Original operating instructions AERO AEROMAT VT WRG 1100 16 Technical specifications 16.1 Data table The.values.can.vary.according.to.the.specific. equipment.configuration. AEROMAT VT WRG 1100 AEROMAT VT WRG 1100 smart Air throughput (with filter) at blower level 1 approx..21.m³/h approx..21.m³/h at blower level 2 approx..37.m³/h approx..37.m³/h at.blower.level.3.(power.level) approx..56.m³/h...
  • Page 21: Product.fiche

    Original operating instructions AERO AEROMAT VT WRG 1100 16.3 Product fiche 1254/2014 1254/2014 Producer SIEGENIA SIEGENIA AEROMAT VT WRG 1100 AEROMAT VT WRG 1100 b Model.identifier smart Energy.consumption.(SEV); −13.6 kWh/(m².·.a);.E −13.6 kWh/(m².·.a);.E Energy.efficiency.class.(SEC.class) −.34.6 kWh/(m².·.a);.A −.34.54 kWh/(m².·.a);.A ―71.2 kWh/(m².·.a);.A+ (according.to.climatic.zone.warm./.average./.cold) ―71.17 kWh/(m².·.a);.A+ d Type WLA./.ZLA WLA./.ZLA e Type.of.drive...
  • Page 22: Eu Declaration Of Conformity With Regard To Ce Marking

    2014/35/EC Low voltage directive EN.60335-1:2012+A11:2014 EN.62233:2008 2014/53/EC RED Directive Electromagnetic.compatibility: EN.301489-1,.V.1.9.2 EN.301.489-17,.V.2.2.1 EN.61000-3-2:2014 EN.61000-3-3:2013 Electrical.safety.-.Establishment.of.information.technology EN.60950-1:2006+A11:2009+A12:2011+A1:2010+A2:2013 Safety.of.persons.in.electromagnetic.fields.(10.MHz.to.300.GHz) EN.62479:2010 Radio.spectrum.matters.-.data.transmission.devices.in.the.2.4.GHz.ISM.band EN 300 328 V1.9.1 2006/42/EC Machinery Directive EN.12100:2010.Risk.assessment 2011/65/EU RoHs EN.50581:2012.Technical.documentation.on.the.evaluation.of.electrical.and.electronic.devices.with. reference.to.the.restriction.of.hazardous.substances This.declaration.is.responsible.for.the.producers./.importers.based.in.the.European.Union.submitted.by: SIEGENIA-AUBI.KG Hardware.and.ventilation.technology Siegen,.2017-10-10 Duisburger Straße 8 57234.Wilnsdorf,.Germany 22/24 03.2022 H47.FENS039EN-05...
  • Page 24 www.siegenia.com...