Siegenia AERO AEROMAT VT RS1 Original Operating Instructions

Siegenia AERO AEROMAT VT RS1 Original Operating Instructions

Sound absorbing ventilator
Hide thumbs Also See for AERO AEROMAT VT RS1:

Advertisement

Quick Links

ORIGINAL OPERATING
INSTRUCTIONS
AERO
AEROMAT VT RS1
Sound absorbing ventilator.
Window systems
Door systems
Comfort systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AERO AEROMAT VT RS1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siegenia AERO AEROMAT VT RS1

  • Page 1 ORIGINAL OPERATING INSTRUCTIONS AERO AEROMAT VT RS1 Sound absorbing ventilator. Window systems Door systems Comfort systems...
  • Page 3: Table Of Contents

    (optional) ............ 14 6.4. Installation.sequence ........8 6.5. Extension.parts ..........9 RECTIFICATION OF MALFUNCTIONS ..16 6.6. Z.profile ............9 12.1. SIEGENIA.Comfort.app ........ 16 MAINS SUPPLY.........10 TECHNICAL SPECIFICATIONS ....17 7.1. Socket.connection ........10 7.2. External.switch.connection ......10 DIMENSIONS ...........17 7.3. Wiring.diagram.series.switch ...... 10 7.4.
  • Page 4: Target Group Of This Documentation

    • If.the.AEROMAT VT RS1.is.to.be.used.in.a.room.with. a.heating.unit.that.draws.air.from.the.room,.prior. authorisation.must.be.obtained.from.the.proper. authorities,.such.as.the.officially.appointed.district. chimney.sweep. Weather.grille:.911.HW;.installation.position:.horizontal • Only.operate.and/or.store.the.AEROMAT VT RS1 at temperatures.between.‒.15.°C.and.+40.°C. • Use.the.AEROMAT VT RS1.only.with.genuine. Weather.grille:.911.HW-g.(concealed.installation.in.the.wall);. accessories.from.SIEGENIA. installation.position:.horizontal • Use.the.AEROMAT VT RS1.only.when.it.is.in.a. technically.sound.condition. • Do.not.modify.the.unit's.components.in.any.way. Weather.grille:.911.CW;.installation.position:.horizontal • Ensure.that.the.ventilation.openings.are.kept.free. and.are.not.blocked.by.other.equipment,.furniture. or.objects. Weather.grille:.911.HS;.installation.position:.vertical • Please.do.not.put.any.objects.on.top.of.the.unit. Weather.grille:.911.CS;.installation.position:.vertical •...
  • Page 5: Safety Notes

    • Comply.with.the.safety.regulations.for.operating. electrical.equipment.and,.if.necessary,.for.ladders,. – Should.a.solid.object.or.any.liquid.get.inside.the. steps.and.work.overhead.or.at.certain.heights. unit,.stop.operation.immediately.and.disconnect. the.AEROMAT VT RS1.from.the.electricity. • Electrically.operated.unit..Risk.of.fatal.injury.from. grid..Check.whether.the.AEROMAT VT RS1.has. electric.shock.or.fire.To.prevent.personal.injury. become.damaged..Have.the.unit.repaired.by.a. or.damage.to.property,.always.comply.with.the. specialist,.if.necessary following.instructions: • Danger.due.to.third.party.attacks.on.SIEGENIA.WIFI. – work.on.a.230.V.AC.mains.power.supply.may. devices!.Please.observe.the.following.notes.to. only.be.performed.by.a.qualified.electrician. protect.your.system.against.attacks.by.third.parties: – If.the.mains.connection.cable.for.the.unit.is. – every.SIEGENIA.WIFI.device.is.protected.by. damaged,.it.must.be.replaced.by.SIEGENIA,.the. two.passwords.(user.and.administrator)..It.is. company's.customer.service.department,.or. essential.that.you.change.these.passwords.after. similarly.qualified.personnel.in.order.to.prevent. the.initial.setup..Do.not.leave.in.the.default. personal.injury.or.damage.to.property. setting.
  • Page 6: General Notes

    Scope of Original.operating.instructions.(item.2) delivery Quick.start.instructions.SIEGENIA.Comfort.app.(item. – Exhaust.air.fan.or.supply.air.fan Membrane.key.(optional) Grit.filter.ISO.Coarse.55%.or.fine.dust.filter.ISO. Function ePM10.50%.(optional) Operation.via.SIEGENIA.Comfort.app – Electrical.slider.(optional) *The quick start instructions for the SIEGENIA Comfort App are located behind the front panel (To open the front panel, see page 14). 6/20 03.2021 H47.FENS082EN-01...
  • Page 7: Assembly

    Original operating instructions AERO AEROMAT VT RS1 Assembly 6.1 Installation options 6.2 Installation requirements Installation.in.the. • AEROMAT VT RS1Install.and.seal.in.accordance.with. wall state-of-the-art.technology. • The.position.from.which.the.outdoor.air.is.drawn. in.must.be.selected.in.such.way.that.any.nearby. AEROMAT VT emission.sources.have.as.little.impact.as.possible.on. the.quality.of.the.air.being.drawn.in. Concealed. • The.maximum.permissible.area.load.is.1,000.kg.per. installation.in.the. wall running.metre.of.ventilator.length. 6.3 Additional requirements for AEROMAT VT AEROMAT VT RS1 smart •...
  • Page 8: Installation.sequence

    Original operating instructions AERO AEROMAT VT RS1 6.4 Installation sequence 4. AEROMAT VT RS1Install.the..in.its.intended. installation.position.and.seal.it.in.accordance.with. 1. Remove.the.AEROMAT VT RS1.carefully.from.the. the.installation.directives.applicable.on.site. packaging.and.do.not.place.it.on.the.weather.grille. or.front.panel..We.recommend.storing.the.unit. 5. Check.AEROMAT VT RS1.for.cleanliness.prior.to. on.a.soft.surface.(e.g..cardboard.or.sheet).during. starting.it.up..Clean.if.necessary.(see."maintenance. installation. and.care".on.page.13). Only.drill.in.through-holes.for.wall.plugs.and. 2. Close.the.sliders.on.the.front.to.prevent.dirt.(e.g.. screws.in.the.area.indicated.(see.marker.tape). dust).from.entering.the.unit.during.installation..If. the.AEROMAT VT RS1.does.not.have.sliders,.tape.up. the.recesses.in.the.front.panel.with.film. 3. Make.sure.that.no.dirt.and.liquids.can.get.inside. AEROMAT.VT.RS1.including.the.weather.grille.prior.
  • Page 9: Extension.parts

    Original operating instructions AERO AEROMAT VT RS1 6.5 Extension parts 6.6 Z profile Screw.on.the.mounting.angle.in.the.area.indicated. First,.fix.the.Z.profile.(optional).to.the.weather.grille. (marker.tape).or.fasten.it.to.the.casing.profiles. using.double-sided.adhesive.tape,.then.drill.and.rivet.it. with.a.rivet..We.recommend.that.you.use.SIEGENIA. aluminium.mounting.angles. AEROMAT VT RS1.with.911.CW.weather.grille AEROMAT VT RS1.with.911.HW.weather.grille Dimension Meaning Assembly.area.for.bracket Screw.and.drilling.area.(e.g..for.wall. plugs.or.mounting.screws) Overall.depth Bracket.20.x.20.x.2.(optional) Z.profile.(optional) Stop.profile.(optional) H47.FENS082EN-01 03.2021 9/20...
  • Page 10: Mains Supply

    Original operating instructions AERO AEROMAT VT RS1 Mains supply 7.3 Wiring diagram series switch Depending.on.the.design,.the.AEROMAT VT RS1 is connected.to.a.suitable.socket.of.the.230-V.AC.mains. power.supply.using.the.Euro.plug.or.directly.to.the. 230-V.AC.mains.power.supply.using.an.external.switch. 7.1 Socket connection When.installed.in.damp.rooms,.the.socket.for.the. AEROMAT VT RS1 must be installed in at least protection.class.3. Transformer 7.2 External switch connection Flat.ribbon.cable WARNING 20 V DC...
  • Page 11: Unit Function

    Original operating instructions AERO AEROMAT VT RS1 Unit function 8.1 Ventilation with blowers 8.2 Ventilation without blowers • The.AEROMAT VT RS1.is.equipped.with.1.supply.air. • The.room.is.ventilated.through.air.pressure. fan.or.with.1.exhaust.air.fan. compensation.of.the.indoor.and.outdoor.air. • Supply.air.fan:.the.outside.air.is.drawn.in.through. (pressure.differential)..As.this.happens,.the.air. the.supply.air.fan.and.enters.the.room.as.supply.air. normally.flows.into.the.room.from.outside. • Exhaust.air.blower:.the.exhaust.air.is.drawn.in. • The.air.flow.into.the.room.varies.as.the.wind. through.the.exhaust.air.fan.and.makes.its.way. pressure.changes.with.the.weather. outside as outgoing air. •...
  • Page 12: Operation

    Original operating instructions AERO AEROMAT VT RS1 10 Operation According.to.the.design,.the.membrane.key.is. 10.2 Adjustment of the blower level using the positioned.on.the.LH.or.RH.in.the. external switch AEROMAT VT RS1..If.it.is.located.on.the.RH.side,.the. membrane.key.is.turned.180°.(see.figure). • You.can.activate.the.required.blower.levels.directly. 1. Open.sliders by.pressing.the.external.switch.(without.relaying). If.the.membrane.key.is.pressed.when.an.external. switch.is.installed,.the.next.blower.level.will.be. activated..Pressing.the.external.switch.again.takes. you.back.to.the.required.blower.level.. 3-stage rotary switch Recommendation:.use.a.3-stage.rotary.switch.provided. onsite. Blower.level.0 Blower.level.1 2.
  • Page 13: Operation Via Smartphone Or Tablet (Aeromat Vt Rs1 Smart Only)

    • Clean.the.AEROMAT VT RS1.with.a.cloth.moistened. indicator.lights. with.a.mild.soap.solution.or.cleaning.agent. ISO ePM10 50% filters must not be cleaned, they must be replaced. Only use the original filters from SIEGENIA. You can purchase replacement filters from SIEGENIA or from specialist retailers. H47.FENS082EN-01 03.2021 13/20...
  • Page 14: Replacing.the.air.canal.and.the.filter (Optional)

    Original operating instructions AERO AEROMAT VT RS1 11.3 Replacing the air canal and the filter (optional) • The.figure.below.shows.the.opening.direction. for a AEROMAT VT RS1.that.has.been.installed. horizontally. • The.position.of.the.components.can.deviate.from. the.figure..Be.sure.to.note.the.arrangement.of. the.internal.parts.for.special.models.that.do.not. correspond.to.the.figure. 1. Open.the.locking.bolts.on.the.RH.and.LH.(or.in.the. middle.according.to.ventilator.length) 2. Pull.out.the.front.panel 3. Slide.the.membrane.key.out.sideways.(if.present) 4. Remove.the.front.profile.and.place.it.on.a.soft. surface.(cardboard,.sheet) 14/20 03.2021 H47.FENS082EN-01...
  • Page 15 Original operating instructions AERO AEROMAT VT RS1 5. Remove.front.profile.insulation.and.filter 10. If.necessary,.clean.the.blower.using.compressed.air. only 6. Remove.the.foam 11. Insert.blower.in.the.new.air.canal 7. Remove.the.supporting.plate,.to.do.this,.press.the. top.toward.the.interior.of.the.unit.and.pull.out.of. 12. Reassemble.the.AEROMAT VT RS1.in.the.reverse. the.bottom order. 8. Open.the.transformer.compartment.and.release.the. 13. After.filter.replacement,.hold.down.the.membrane. blower.cable.from.the.circuit.board key.for.5.seconds.to.reset.the.LED.indicator.(filter. replacement.indicator). 9. Carefully.take.out.the.air.canal/foam.element.and. remove.the.blower H47.FENS082EN-01 03.2021 15/20...
  • Page 16: Rectification Of Malfunctions

    Restart.WIFI.router.of.the.home.network router.of.the.home.network No.WIFI.connection.to.the. Restart.smartphone/tablet smartphone/tablet AEROMAT VT RS1 smart Reset.on.the.AEROMAT VT RS1 smart: does.not.respond.to. 1..Press.membrane.key.3.times.briefly.in. smartphones/tablets succession No.WIFI.connection.to.the. 2..Then.immediately.press.and.hold.the. AEROMAT VT RS1 smart membrane.key.once.(for.approx..4.seconds) 3..The.AEROMAT VT RS1 smart.has.been.reset.to. the.factory.settings. 12.1 SIEGENIA Comfort app Note:.you.will.find.detailed.information.on.how.to. rectify.malfunctions.on.the.SIEGENIA.Smarthome. Internet.page.. www.siegenia.com/qr/comfort-app/faq 16/20 03.2021 H47.FENS082EN-01...
  • Page 17: Technical Specifications

    Original operating instructions AERO AEROMAT VT RS1 13 Technical specifications AEROMAT VT RS1 (Supply air) Air throughput (with filter) at blower level 1 approx..27.m³/h at blower level 2 approx..43.m³/h at.blower.level.3.(power.level) approx..62.m³/h Inherent noise 1, 2 at blower level 1 .= 17 dB.(A) at blower level 2 .= 26 dB.(A) at.blower.level.3.(power.level)
  • Page 18: Information Requirements

    Original operating instructions AERO AEROMAT VT RS1 15 Information requirements according to EU Regulation 1253/2014 Producer SIEGENIA b Model.identifier AEROMAT VT RS1 Energy.consumption.(SEV); − 0.8 kWh/(m².·.a);.F − 8.4 kWh/(m².·.a);.F Energy.efficiency.class.(SEC.class) −21.8 kWh/(m².·.a);.D (according.to.climatic.zone.warm./.average./.cold) d Type WLA./.ELA e Type.of.drive Multi-stage.drive Heat.recovery.system ― Thermal.efficiency ― h Maximum.flow.rate 62.m³/h...
  • Page 19: Eu Declaration Of Conformity With Regard To Ce Marking

    2014/35/EC Low voltage directive EN.60335-1:2012+A11:2014 EN.62233:2008 2014/53/EC RED Directive Electromagnetic.compatibility: EN.301489-1,.V.1.9.2 EN.301.489-17,.V.2.2.1 EN.61000-3-2:2014 EN.61000-3-3:2013 Electrical.safety.-.Establishment.of.information.technology EN.60950-1:2006+A11:2009+A12:2011+A1:2010+A2:2013 Safety.of.persons.in.electromagnetic.fields.(10.MHz.to.300.GHz) EN.62479:2010 Radio.spectrum.matters.-.data.transmission.devices.in.the.2.4.GHz.ISM.band EN 300 328 V1.9.1 2006/42/EC Machinery Directive EN.12100:2010.Risk.assessment 2011/65/EU RoHs EN.50581:2012.Technical.documentation.on.the.evaluation.of.electrical.and.electronic.devices.with. reference.to.the.restriction.of.hazardous.substances This.declaration.is.responsible.for.the.producers./.importers.based.in.the.European.Union.submitted.by: SIEGENIA-AUBI.KG Hardware.and.ventilation.technology Siegen,.2017-10-10 Duisburger Straße 8 57234.Wilnsdorf,.Germany H47.FENS082EN-01 03.2021 19/20...
  • Page 20 www.siegenia.com...