Siegenia AERO AEROMAT VT WRG 1000 Operating And Care Instructions

Siegenia AERO AEROMAT VT WRG 1000 Operating And Care Instructions

Sound absorbing ventilator with heat recovery
Hide thumbs Also See for AERO AEROMAT VT WRG 1000:

Advertisement

Quick Links

AEROMAT VT WRG 1000.
Sound absorbing ventilator with heat recovery.
WI N D OW HAR DWA RE
D O OR H AR DWA RE
S L I D I N G D O O R H A R DWA R E
VE NT IL AT I O N T EC HN O LO GY
B U I L D I N G T EC HN O LO GY
OPERATING AND CARE
I N S T R U C T I O N S
V ENTI L AT IO N T EC HN OLOGY
AE RO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AERO AEROMAT VT WRG 1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siegenia AERO AEROMAT VT WRG 1000

  • Page 1 OPERATING AND CARE I N S T R U C T I O N S AEROMAT VT WRG 1000. Sound absorbing ventilator with heat recovery. WI N D OW HAR DWA RE D O OR H AR DWA RE V ENTI L AT IO N T EC HN OLOGY S L I D I N G D O O R H A R DWA R E VE NT IL AT I O N T EC HN O LO GY AE RO...
  • Page 3: Table Of Contents

    Operating and Care Instructions AEROMAT VT WRG 1000 Intended use ....................................2 Safety notices ....................................2 Function......................................3 Commissioning ....................................4 Operation ......................................4 Malfunctions and warning messages ............................7 Care and maintenance ...................................7 Technical specifications ................................11 Liability ......................................12 Last update: 28.11.2013...
  • Page 4: Intended Use

    • Only insert the Euro plug of the network connection cable into a suitable 230-V AC mains power supply. • If the network connection cable is damaged, it may only be replaced by SIEGENIA, its customer service department or a qua- lified electrician.
  • Page 5: Function

    Operating and Care Instructions AEROMAT VT WRG 1000 Function Ventilation with blowers and heat recovery (schematic diagram) • The outdoor air (1) is drawn in through the outdoor air filter (2) or insect grille (2, optional) using the supply air blower (3) and enters the room as supply air (4).
  • Page 6: Commissioning

    AEROMAT VT WRG 1000 Operating and Care Instructions Commissioning Automatic calibration of the CO and VOC sensors (if installed) Important: The membrane key must not be pressed during the process in order to prevent incorrect calibration. • The sensors are calibrated automatically as soon as the AEROMAT VT WRG 1000 is connected to the mains power supply (and also following a power failure).
  • Page 7 Operating and Care Instructions AEROMAT VT WRG 1000 Setting the blower level (using the membrane key) • By pressing the membrane key several times, you can activate the required blower levels and automatic mode (relaying). • Automatic blower mode is only available if the unit has been fitted with sensors. •...
  • Page 8 AEROMAT VT WRG 1000 Operating and Care Instructions Setting the blower level (using the external switch) • By pressing the external switch, you can activate the required blower levels and automatic mode directly (without relaying). • Attention! If the membrane key is pressed when an external switch is installed, the next blower level will be activated (for sequence see page 5).
  • Page 9: Malfunctions And Warning Messages

    LEDs do not flash Replace the filters* Membrane key flashes blue You can purchase replacement filters * Important: Filters must be replaced not cleaned. Only use genuine filters from SIEGENIA. from SIEGENIA or from specialist retailers. Description Contents Material number...
  • Page 10 AEROMAT VT WRG 1000 Operating and Care Instructions Removing the front panel The figure below shows the opening direction for a AEROMAT VT WRG 1000 that has been installed horizontally. 1. Open the locking bolts on the right and left 2.
  • Page 11 Operating and Care Instructions AEROMAT VT WRG 1000 Replacing the outdoor air filter/cleaning the insect grille (subject to design) 1. Remove the front panel (also see page 8) 2. Remove the insulation 3. Remove the filter compartment cover 4a. Remove the outdoor air filter and dispose of it as household waste 4b.
  • Page 12 AEROMAT VT WRG 1000 Operating and Care Instructions Cleaning the heat exchanger 1. Remove the front panel (also see page 8) 2. Remove the exhaust air filter (also see page 9) 3. Turn the supporting bracket 90° 4. Undo the fixing screw for the cover 5.
  • Page 13: Technical Specifications

    Operating and Care Instructions AEROMAT VT WRG 1000 Technical specifications Specifications for a heat recovery unit = 46 dB Sound absorption (with locking bolts open) w-1.9 = 53 dB n,e,w Max. permissible area load per running metre of ventilator 1,000 kg length Heat transfer coefficient U = 0.55 W/m...
  • Page 14: Liability

    Environmental protection Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act, SIEGENIA will continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are ha- zardous to the environment as soon as this becomes technically feasible.
  • Page 16 Switzerland Phone: +41 33 3461010 You can fi nd address details for our Germany Phone: +49 271 39310 Turkey Phone: +90 216 5934151 international sites at: www.siegenia.com Great Britain Phone: +44 2476 622000 Ukraine Phone: +380 44 4637979 Contact your dealer:...

Table of Contents