Siegenia AERO AEROMAT VT WRG 1000 Original Operating Instructions

Siegenia AERO AEROMAT VT WRG 1000 Original Operating Instructions

Hide thumbs Also See for AERO AEROMAT VT WRG 1000:

Advertisement

Quick Links

ORIGINAL OPERATING
INSTRUCTIONS
AERO
AEROMAT VT WRG 1000
Sound absorbing ventilator.
Window systems
Door systems
Comfort systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AERO AEROMAT VT WRG 1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Siegenia AERO AEROMAT VT WRG 1000

  • Page 1 ORIGINAL OPERATING INSTRUCTIONS AERO AEROMAT VT WRG 1000 Sound absorbing ventilator. Window systems Door systems Comfort systems...
  • Page 3: Table Of Contents

    General faults ..........20 8.1.1. Wiring.diagram.series.switch ......10 15.2 Fault messages ..........20 8.1.2. Wiring.diagram.3-stage.rotary.switch ....10 15.3. SIEGENIA.Comfort.app ........ 20 UNIT FUNCTION ........11 TECHNICAL SPECIFICATIONS ....21 9.1. Ventilation.without.blowers ......11 9.2. Ventilation.with.blowers ......11 16.1 Data table ............ 21 9.3.
  • Page 4: Target Group Of This Documentation

    Weather.grille:.HW-g.(concealed.installation.in. gas.systems.of.solid.fuel.heating.units.must.be.able. the.wall);.installation.position:.horizontal to.be.shut.off. • Only. o perate. a nd/or. s tore. t he. A EROMAT VT WRG 1000 at.temperatures.between.‒.15.°C.and.+40.°C. • Use.the.AEROMAT VT WRG 1000.only.with.genuine. Weather.grille:.CW;.installation.position:.horizontal accessories.from.SIEGENIA. • Use.the.AEROMAT VT WRG 1000.only.when.it.is.in.a. technically.sound.condition. Weather.grille:.HS;.installation.position:.vertical • Do.not.modify.the.unit's.components.in.any.way. • Ensure.that.the.ventilation.openings.are.kept.free. and.are.not.blocked.by.other.equipment,.furniture. Weather.grille:.CS;.installation.position:.vertical or.objects.
  • Page 5: Safety Notes

    – Should.a.solid.object.or.any.liquid.get.inside.the. understand.the.resulting.risks..Children.must.not. unit,.stop.operation.immediately.and.disconnect. play.with.the.unit..Cleaning.and.user.maintenance. the.AEROMAT VT WRG 1000.from.the.electricity. may.not.be.carried.out.by.unsupervised.children. grid..Check.whether.the. AEROMAT VT WRG 1000.has.become.damaged.. • Comply.with.the.safety.regulations.for.operating. Have.the.unit.repaired.by.a.specialist,.if. electrical.equipment.and,.if.necessary,.for.ladders,. necessary steps.and.work.overhead.or.at.certain.heights. • Danger.due.to.third.party.attacks.on.SIEGENIA.WIFI. • Electrically.operated.unit..Risk.of.fatal.injury.from. devices!.Please.observe.the.following.notes.to. electric.shock.or.fire..To.prevent.personal.injury. protect.your.system.against.attacks.by.third.parties: or.damage.to.property,.always.comply.with.the. following.instructions: – every.SIEGENIA.WIFI.device.is.protected.by. two.passwords.(user.and.administrator)..It.is. – all.work.on.a.230.V.AC.mains.power.supply.may. essential.that.you.change.these.passwords.after. only.be.performed.by.a.qualified.electrician. the.initial.setup..Do.not.leave.in.the.default. setting.
  • Page 6: General Notes

    Original.operating.instructions ● ● Quick.start.instructions.SIEGENIA.Comfort.app. – ● The quick start instructions for the SIEGENIA Comfort app are located behind the front panel (To open the front panel, see page 17). Equipment AEROMAT VT WRG 1000 AEROMAT VT WRG 1000 name smart Operation.via.membrane.key...
  • Page 7: Assembly

    Original operating instructions AERO AEROMAT VT WRG 1000 Assembly 7.1 Installation options 7.2 Installation requirements Installation.in.the. • The.position.from.which.the.outdoor.air.is.drawn. wall in.must.be.selected.in.such.way.that.any.nearby. emission.sources.have.as.little.impact.as.possible.on. the.quality.of.the.air.being.drawn.in. AEROMAT VT • The.maximum.permissible.area.load.is.1,000.kg.per. running.metre.of.ventilator.length. Concealed. 7.3 Additional requirements for installation.in.the. wall.with.wall.duct AEROMAT VT WRG 1000 smart • The.AEROMAT VT WRG 1000.smart.should.be. AEROMAT VT installed.to.be.as.free.from.interference.as.possible..
  • Page 8: Installation.sequence

    Original operating instructions AERO AEROMAT VT WRG 1000 7.4 Installation sequence 4. AEROMAT VT WRG 1000.Install.the.in.its.intended. installation.position.and.seal.it.in.accordance.with. 1. Remove.the.AEROMAT VT WRG 1000.carefully.from. the.installation.directives.applicable.on.site. the.packaging.and.do.not.place.it.on.the.weather. grille.or.front.panel..We.recommend.storing.the.unit. 5. Check.AEROMAT VT WRG 1000.for.cleanliness. on.a.soft.surface.(e.g..cardboard.or.sheet).during. prior.to.starting.it.up..Clean.if.necessary.(see. installation. "maintenance.and.care".on.page.17). Only.drill.in.through-holes.for.wall.plugs.and. 2. Close.the.sliders.on.the.front.to.prevent.dirt.(e.g.. screws.in.the.area.indicated.(see.marker.tape). dust).from.entering.the.unit.during.installation..If. the.AEROMAT VT WRG 1000.does.not.have.sliders,. tape.up.the.recesses.in.the.front.panel.with.film.
  • Page 9: Extension.parts

    Original operating instructions AERO AEROMAT VT WRG 1000 7.5 Extension parts 7.6 Z profile Screw.on.the.mounting.angle.in.the.area.indicated. First,.fix.the.Z.profile.(optional).to.the.weather.grille. (marker.tape).or.fasten.it.to.the.casing.profiles. using.double-sided.adhesive.tape,.then.drill.and.rivet.it. with.a.rivet..We.recommend.that.you.use.SIEGENIA. aluminium.mounting.angles. AEROMAT VT WRG 1000.with.weather.grille.CW AEROMAT VT WRG 1000.with.weather.grille.HW Dimension Meaning Assembly.area.for.bracket Screw.and.drilling.area.(e..g..for.wall. plugs.or.mounting.screws) Overall.depth Bracket.20.x.20.x.2.(optional) Z.profile.(optional) Stop.profile.(optional) H47.FENS037EN-03 03.2021 9/24...
  • Page 10: Mains Supply

    Original operating instructions AERO AEROMAT VT WRG 1000 Mains supply 8.1 External switch connection WARNING Exposed.electrical.components Risk of fatal injury from electric shock or fire • all.work.on.a.230.V.AC.mains.power.supply.may.only.be. performed.by.a.qualified.electrician. • All.work.on.the.230.V.AC.mains.power.supply.must.be. carried.out.in.compliance.with.the.current.German.VDE. regulations.(e..g.,.VDE.0100).and.any.relevant.country- specific.requirements. • Switch.off.or.unscrew.the.security.devices. If.the.AEROMAT VT WRG 1000.is.connected.directly. to.the.230.V.AC.mains.power.supply,.the.customer. must install a mains isolator.
  • Page 11: Unit Function

    Original operating instructions AERO AEROMAT VT WRG 1000 Unit function 9.1 Ventilation without blowers 9.2 Ventilation with blowers • The.room.is.ventilated.through.air.pressure. • The.outside.air.(2).is.drawn.in.and.enters.the.room. compensation.between.the.indoor.and.outdoor. as.filtered.supply.air.(10). air.(pressure.differential)..As.this.happens,.the.air. normally.flows.into.the.room.from.outside. • The.exhaust.air.(11).is.drawn.in.and.is.released.into. the.atmosphere.as.exhaust.air.(1). • The.air.flow.into.the.room.varies.as.the.wind. pressure.changes.with.the.weather. • Both.air.flows.drawn.through.the.heat.exchanger. (4)..Here,.particularly.during.cold.times.of.the.year,. the.outside.air.is.pre-heated.by.the.warm.exhaust. air.before.it.enters.the.room.as.supply.air. Item value Exhaust.air Outside air Exhaust.air.fan Heat.exchanger...
  • Page 12: (Units.with.exhaust.air.sensor)

    Original operating instructions AERO AEROMAT VT WRG 1000 9.3 Ventilation in automatic mode 9.4 Frost protection control (units with exhaust air sensor) • The.supply.air.blower.is.switched.off.automatically. • The.blower.levels.0,.1.and.2.are.controlled.in. as.soon.as.the.outside.temperature.drops.below. automatic.mode..The.required.blower.level.is. ‒15.°C..The.exhaust.air.blower.continues.to.run. activated.by.means.of.the.critical.value. • As.soon.as.the.outside.temperature.increases.above. • The.blowers.are.not.switched.off,.but.continue.to. -15.°C.again,.the.device.switches.to.the.last.level.to. run at a minimum level. be used.
  • Page 13: Commissioning

    .and.TVOC.sensors,. 1. Air.the.room.thoroughly.for.10.min. a.one-off.calibration.of.the.sensors.is.performed. during.the.commissioning..The.sensors.adapt.to.the. 2. Switch.AEROMAT VT WRG 1000.to.the.electricity. environment. grid. • The.room.temperature.must.be.between.4.°C.and. 3. The.exhaust.air.sensors.automatically.start.a. 50.°C. warming-up.phase.(duration.approx..5.min.): 2.LEDs.flash.red • The.calibration.lasts.24.hours. membrane.key.flashes.blue • The.automatic.mode.already.functions.during.the. 4. The.calibration.starts.automatically. calibration. • AEROMAT VT WRG 1000.smart:.the.air.quality. is.already.displayed.during.the.calibration.in.the. SIEGENIA.Comfort.app. • The.accuracy.of.the.sensor.rises.with.the.continuing. duration.of.the.calibration. H47.FENS037EN-03 03.2021 13/24...
  • Page 14: Operation

    Original operating instructions AERO AEROMAT VT WRG 1000 12 Operation 12.1 Ventilation without blowers 12.3 Adjustment of the blower level using the membrane key • By.pressing.the.membrane.key.several.times,.you. can.activate.the.required.blower.levels.(relaying). • After.a.power.failure,.the.unit.switches.to.the.last. level to be used. Switching sequence (units without exhaust air sensors) Blower.level.0 Blower.level.1 Blower.level.2...
  • Page 15: Adjustment.of.the.blower.level.using The.external.switch

    Original operating instructions AERO AEROMAT VT WRG 1000 12.4 Adjustment of the blower level using the 3-stage rotary switch (units without exhaust air sensors) external switch Blower.level.0 Blower.level.1 • You.can.activate.the.required.blower.levels.directly. by.pressing.the.external.switch.(without.relaying). • After.a.power.failure,.the.unit.switches.to.the.last. level to be used. • If.the.membrane.key.is.pressed.when.an.external. switch.is.installed,.the.next.blower.level.will.be. Blower.level.2 Power level activated..Pressing.the.external.switch.again.takes.
  • Page 16: Operation.via.smartphone.or.tablet (Aeromat.vt.wrg.1000.Smart.only)

    12.5 Operation via smartphone or tablet 12.5.1 Teaching in the unit (AEROMAT VT WRG 1000 smart only) Please.follow.the.enclosed.(Quick.start.instructions).to. The.AEROMAT VT WRG 1000.smart.can.be.controlled. integrate.the.unit.in.your.home.WIFI. by.a.tablet.or.smartphone.and.offers.additional.device. functions.via.the.SIEGENIA.Comfort.app. 12.5.2 Unit functions in the app Blower performance • The.blower.performance.can.be.set.manually. • On.application.of.the.automatic.mode,.the.manually. adjusted.blower.performance.is.overridden. Automatic mode •...
  • Page 17: Maintenance

    • Clean.the.AEROMAT VT WRG 1000.with.a.cloth. 1. Open.the.locking.bolt. moistened.with.a.mild.soap.solution.or.cleaning. agent. 13.2 Maintenance intervals Changing the filter Replace.filter.every.12.months.or.when.the.filter. change.indicator.lights.up. Filters.must.be.replaced,.not.cleaned..Only.use. genuine.filters.from.SIEGENIA..You.can.purchase. replacement.filters.from.SIEGENIA or from specialist.retailers. Cleaning the air passages and heat exchanger Check.and.clean.air.passages.and.heat.exchanger.every. 12.months. 2. Pull.out.the.front.panel. Condensation.does.not.generally.develop..If.the. 3. Slide.the.membrane.key.out.sideways.(if.present). surface.of.the.heat.exchanger.becomes.wet.for.a. short.period,.as.can.happen.in.damp.locations,.for. 4. Remove.the.front.profile.and.place.it.on.a.soft.
  • Page 18: Changing.the.supply.air.filter

    Original operating instructions AERO AEROMAT VT WRG 1000 13.4 Changing the supply air filter 13.5 Replacing the exhaust air filter 1. Remove.the.front.panel.(see.page.17). 1. Remove.the.front.panel.(see.page.17). 2. Remove.the.insulation. 2. Remove.the.retention.springs. 3. Remove.the.filter.compartment.cover. 3. Remove.the.exhaust.air.filter.and.dispose.of.it.as. household.waste. 4. Remove.the.supply.air.filter. 4. Insert.a.new.exhaust.air.filter. 5. Insert.the.new.supply.air.filter. 5. Reassemble.the.AEROMAT VT WRG 1000.in.the. 6.
  • Page 19: Cleaning.the.heat.exchanger

    Original operating instructions AERO AEROMAT VT WRG 1000 13.6 Cleaning the heat exchanger Caution!.Sharp.edges.on.the.casing.profile.-.Wear. 5. Remove.the.cover. protective.gloves! 6. Remove.the.foam.padding.if.necessary.(if.present). 1. Remove.the.front.panel.(see.page.17). 7. Remove.the.heat.exchanger.and.clean.it.thoroughly. 2. Remove.the.exhaust.air.filter.(see.page.18). under running water. 3. Turn.the.supporting.piece.90°. 8. Leave.the.heat.exchanger.to.dry.completely. 4. Loosen.the.fixing.screw.for.the.cover. 9. Insert.the.cleaned.heat.exchanger.so.that.it.is. sealed.on.all.sides.in.the.casing. 10. Reassemble.the.AEROMAT VT WRG 1000.in.the. reverse order.
  • Page 20: Troubleshooting

    Solution 1.LED.flashes.red Filter soiled. Change.the.filter.(see.page.21). As.soon.as.the.outside.temperature. 2.LEDs.flash.red. The.frost.protection.control.is. increases.above.-15.°C.again,.the. alternately active. device.switches.to.the.last.level.to.be. used. membrane.key.flashes. Sensor.is.defective. Contact.specialist.company. blue The filter change is displayed in addition to the current operating status. 15.3 SIEGENIA Comfort app You.will.find.detailed.information.on.how.to.rectify. malfunctions.on.the.SIEGENIA.Smarthome.Internet. page. www.siegenia.com/qr/comfort-app/faq 20/24 03.2021 H47.FENS037EN-03...
  • Page 21: Technical Specifications

    Original operating instructions AERO AEROMAT VT WRG 1000 16 Technical specifications 16.1 Data table The.values.can.vary.according.to.the.specific. equipment.configuration. AEROMAT VT WRG 1000 AEROMAT VT WRG 1000 smart Air throughput (with filter) at blower level 1 approx..22.m³/h approx..22.m³/h at blower level 2 approx..38.m³/h approx..38.m³/h at.blower.level.3.(power.level) approx..52.m³/h...
  • Page 22: Product.data.sheet

    Original operating instructions AERO AEROMAT VT WRG 1000 16.3 Product data sheet 1254/2014 1254/2014 Producer SIEGENIA SIEGENIA AEROMAT VT WRG 1000 AEROMAT VT WRG 1000 b Model.identifier smart Energy.consumption.(SEV); −11.2 kWh/(m².·.a);.E −11.7 kWh/(m².·.a);.E Energy.efficiency.class.(SEC.class) −32.0 kWh/(m².·.a);.B −32.5 kWh/(m².·.a);.B (according.to.climatic.zone.warm./.average./.cold) −68.2 kWh/(m².·.a);.A+ −68.6 kWh/(m².·.a);.A+ d Type WLA./.ZLA WLA./.ZLA...
  • Page 23: Eu Declaration Of Conformity With Regard To Ce Marking

    2014/35/EC Low voltage directive EN.60335-1:2012+A11:2014 EN.62233:2008 2014/53/EC RED Directive Electromagnetic.compatibility: EN.301489-1,.V.1.9.2 EN.301.489-17,.V.2.2.1 EN.61000-3-2:2014 EN.61000-3-3:2013 Electrical.safety.-.Establishment.of.information.technology EN.60950-1:2006+A11:2009+A12:2011+A1:2010+A2:2013 Safety.of.persons.in.electromagnetic.fields.(10.MHz.to.300.GHz) EN.62479:2010 Radio.spectrum.matters.-.data.transmission.devices.in.the.2.4.GHz.ISM.band EN 300 328 V1.9.1 2006/42/EC Machinery Directive EN.12100:2010.Risk.assessment 2011/65/EU RoHs EN.50581:2012.Technical.documentation.on.the.evaluation.of.electrical.and.electronic.devices.with. reference.to.the.restriction.of.hazardous.substances This.declaration.is.responsible.for.the.producers./.importers.based.in.the.European.Union.submitted.by: SIEGENIA-AUBI.KG Hardware.and.ventilation.technology Siegen,.2017-09-22 Duisburger Straße 8 57234.Wilnsdorf,.Germany H47.FENS037EN-03 03.2021 23/24...