Grid-tie transformerless solar inverter
Table of Contents

Advertisement

Maintenance
- Item : String Fuse (source 1)
- Part number : 10GPV15U0
- Rate amp : 15 A
- Rate voltage : 1000 V
- Manufacturers : Hollyland
Please check the fuses if the power generation of inverter is abnormal.
1. Switch AC and DC power off and wait until LCD display turn off.
2. Loosen the 4 screws on the front cover. (Figure 5-2)
3. Pull out the fuse holder and check the fuse. (Figure 5-6)
4. Replace the fuse if necessary.
5. Reassemble the inverter. Please be careful the waterproof tape for ensure
the protection degree.
Figure 5-6 : Pull out the fuse
48
- Item : String Fuse (source 2)
- Part number : 0SPF015.T
- Rate amp : 15 A
- Rate voltage : 1000 V
- Manufacturers : Littelfuse