5.3 Operating the device

5.3.1 Install the device correctly
according to the installation steps.
The operator is facing the device,
and the water control knob on the
handpiece cord is adjusted to the
maximum.
5.3.2 Press the power switch on the
main unit. At this time, the scaling
mode
indicator is lit. The power
display window shows 05. The power
indicator lights half, and the bottle
water supply mode indicator is lit.
5.3.3 Select the bottle water supply
mode or external water supply mode
(the mode indicator corresponding to
the selected water supply mode is
lit).
5.3.4 Select the appropriate working
tip as required, and tighten it to the
handpiece by using the provided
wrench.
5.3.5 Hold the handpiece according
to the using habits, generally
adopting the pen holding position.
5.3.6 When the device is working
normally, the frequency is extremely
fast. When scaling, ensure that the
tip vibrates normally and the water is
atomized normally, then gently touch
the tooth surface and reciprocate at a
certain speed to remove the dental
calculus. Keep the water flow
smoothly to avoid tip overheat. Never
use excessive force or stay for too
long when cleaning the teeth.
5
Product function and use
5.3.7 Power adjustment: Adjust the
power depending on the application.
Generally, the medium power is
enough, and the output power can
be adjusted at any time in clinical
practice according to the sensitivity
of the patient's teeth and the
hardness of the calculus.
5.3.8 Water flow adjustment: Step on
the foot pedal to activate the tip
vibration. Turn the water control knob
on the main unit or the water control
knob on the handpiece cord to form
water spray to cool the tip and the
cleaned tooth surface.
5.3.9 During clinical use, the cusp of
the tip should not be in vertical
contact with the tooth surface, and
heavy pressure should not be
applied in order to avoid any damage
to the tooth and the tip.
5.3.10 After the operation is
completed, adjust the water control
knob on the handpiece cord to the
maximum, let the device work for
about 30 seconds to rinse the
handpiece and the tip, and then
remove the handpiece and the tip for
cleaning, disinfection and
sterilization.