Technical Specifications; Pump Specifications; Ambient Conditions; Tightening Torques - VERDER VERDERFLEX Dura 80 Operating Manual

Peristaltic hose pump
Table of Contents

Advertisement

11. Technical specifications
11.1 Pump specifications
Size
Max. delivery pressure
Temperature of pumped
liquid
Max. continuous operation
pump speeds
Dimensions

Table 12. - Pump specifications

11.2 Ambient conditions

Operation under any other ambient condition would require
approval from the manufacturer
Operating conditions
Ambient temperature –5 °C to +45 °C
Relative humidity (non-condensing), long-term ≤ 85 %
All units/calculations are based on operating conditions
below 1000 m. For use above this height please check with
manufacturer or local representative for confirmation of
performance.
Storage conditions
Ambient temperature +10 °C to +50 °C
Relative humidity (non-condensing), long-term ≤ 85 %

11.3 Tightening torques

Tightening torques should be applied at the following torque
values:
Position
Inspection Window
Port Flange
Rotor Shoe
Gearbox to GMU adaptor
Motor to Gearbox
Frames to Casing
Front Cover
Seal plate, filler port &
service cover
Taperlock bush
GMU adaptor to housing

Table 13. - Tightening torques

Original instructions (en)
Value
16 bar
< 100 °C
< 40 °C (ATEX)
40 rpm at 0 bar
40 rpm at 6 bar
26 rpm at 10 bar
18 rpm at 16 bar
*(refer to pump datasheet)
Torque Values (Nm)
3.4 Nm
90 Nm
150 Nm
145 Nm (305 gearbox size)
230 Nm (306 gearbox size)
87 Nm (112/132 size motor)
150 Nm (160/180 size motor)
100 Nm
100 Nm
3.4 Nm
116 Nm
160 Nm
Version 00
© Verder Liquids B.V
Dura 80 - Operating manual

11.4 Preservatives

Use RUST-BAN 335 or similar preservatives on
bare metal.
11.5 Cleaning agents (after hose is
removed)
Cleaning Agents
Wax solvents, diesel paraffin, alkaline cleaners, warm water

Table 14. - Cleaning agents

11.6 Lubricants

Recommended lubricants for longer hose life are
VERDERLUBE or VERDERSIL.
Pump Type
Amount of Lubricant
Dura 80
35 Litres (9.2 US Gallons)

Table 15. - Lubricant

Note
The pump lubricant is filled to the lowest screw of the hole of
the inspection window.
11.7 Solids size handling
Solid type
Size of solid
Hard solid
< 8mm
Compressible solid
< 20mm

Table 16. - Solids size handling

For more information about specific solids handling,
please consult your Verder representative.
33 | Page