Possible cause
Incorrect lubricant
Low lubricant level
X
-
-
-
Product ambient temperature too high
Over shimming of the pump
Blocked suction / bad suction characteristics / no
X
X
-
-
product
X
-
X
-
High pump speed
Suction / discharge valve closed
Hose failure
Poor pump selection, incorrect shoe shimming
Suction line too long
-
X
-
-
Pump speed too high
Suction line bore too small
High product viscosity
Suction / discharge lines not secured properly
Original instructions (en)
Solution
Consult the manufacturer to obtain correct
X
lubricant.
Add required amount
X
Consult the manufacturer regarding
X
maximum temperature
Check for and remove excess shims
X
Check pipework and valves for blockages.
X
Check that the suction pipework is as short
X
and as large in diameter as feasible
Correct the piping layout
X
Consult the manufacturer
X
Reduce speed to a minimum
X
Consult the manufacturer
X
Open suction / discharge valve
X
Replace hose (g 8.6 Hose change)
X
Consult the manufacturer to check pump
X
selection
Consult the manufacturer
X
Consult the manufacturer
X
Consult the manufacturer
X
Consult the manufacturer
X
Check and secure suction / discharge lines