11. Technical specifications
11.1 Pump specifications
Size
Max. delivery pressure
Temperature of pumped
liquid
Max. continuous operation
pump speeds
Dimensions
Table 11. - Pump specifications
11.2 Ambient conditions
Operation under any other ambient condition would require
approval from the manufacturer
Operating conditions
•
Ambient temperature –5 °C to +45 °C
•
Relative humidity (non-condensing) – long—term ≤ 85 %
•
All units/calculations are based on operating conditions
below ≤ 1000 m. For use above this height please check
with manufacturer or local representative for confirmation of
performance.
Storage conditions
•
Ambient temperature +10 °C to +50 °C
•
Relative humidity (non-condensing) – long—term ≤ 85 %
11.3 Tightening torques
Tightening torques should be applied at the following torque
values:
Position
Inspection Window
Port Flange
Rotor Shoe
Gearbox to Pump Housing
Motor to Gearbox
Frames to Casing
Front Cover
Keyless Bush
Seal Plate
Table 12. - Tightening torques
Original instructions (en)
Value
16 bar
< 100 °C
< 40 °C (ATEX)
60 rpm at 0 bar
55 rpm at 6 bar
37 rpm at 10 bar
27 rpm at 16 bar
*(refer pump datasheet)
Torque Values (Nm)
3.4 Nm
90 Nm
50 Nm
65 Nm
65 Nm (301 gearbox size)
90 Nm (303 gearbox size)
35 Nm
27 Nm
35 Nm
3.4 Nm
Version 01
© Verder Liquids B.V
Dura 55 series - Operating manual
11.4 Preservatives
Use RUST-BAN 335 or similar preservatives on
bare metal.
11.5 Cleaning agents (after hose is
removed)
Cleaning Agents
Wax solvents, diesel paraffin, alkaline cleaners, Warm
Water
Table 13. - Cleaning agents
11.6 Lubricants
Recommended lubricants for longer hose life are
VERDERLUBE or VERDERSIL.
Pump Type
Amount of Lubricant
Dura 55/ 55HF
15 Litres (3.96 US Gallons)
Table 14. - Lubricant
Note
The pump lubricant is filled to the lowest screw of the hole of the
inspection window.
11.7 Number of shims required
Number of shims required remains unaffected by change
in rpm of the pump. Each shim is 0.5mm thick.
Hose Material
0 Bar
EPDM
2
NR
2
NBR
1
NBRF
1
CSM
1
Table 15. - Number of shims required
11.8 Rotor setting distance
The rotor is factory aligned, but for maintenance or
assembly from flat pack the rotor setting distance should
be known.
Pump Type
Rotor Setting Distance
Dura 55/ 55HF
4mm from the front of casing to the front
of rotor shoe
Table 16. - Rotor setting distance
6 Bar
10 Bar
16 Bar
3
5
6
3
5
6
2
4
N/A
2
N/A
N/A
2
4
6
30 | Page