ƒ set the maximum desired heating value (rpm) with the
Enter
selection with
ƒ Once the required output has been set (maximum heating), put the value on the self-adhe-
sive label on the back cover of this manual. For subsequent controls and adjustments, refer
to the set value.
b
The calibration does not entail the ignition of the boiler.
The boiler is delivered with the adjustments shown in the technical data table.
Depending on plant engineering requirements or regional flue gas emission limits it is, however,
possible to modify this value, referring to the graphs below.
8000
7600
7200
6800
6400
6000
5600
5200
4800
4400
4000
3600
3200
2800
2400
2000
1600
1200
800
2
4
6
8
10
Curva portata termica - giri ventilatore
7600
7200
6800
6400
6000
5600
5200
4800
4400
4000
3600
3200
2800
2400
2000
1600
1200
800
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32
20
and
keys, confirming the
Residence 25 KIS
HTG curve (Qn heating)
12
14
16
18
20
22
24
Heat output (kW)
Portata termica (kW)
Residence 30 KIS
Caldaia Family CX 30
HTG curve (Qn heating)
Heat output (kW)
Portata termica (kW)
8400
8000
7600
7200
6800
6400
6000
5600
5200
4800
4400
4000
3600
3200
2800
2400
2000
1600
1200
800
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38
7600
7200
6800
6400
6000
5600
5200
4800
4400
4000
3600
3200
2800
2400
2000
1600
1200
800
400
0
0
2
4.19
Lights and faults
When there is a fault the icon
backlight blinks for 1min with a frequency of 1sec ON and 1sec OFF after which it switches off;
while the bell continues to flash. On the 4 digits of the display a scrolling message that describes
the error code is shown.
26
28
30
When a fault occurs the following icons can appear:
it comes on when there is a flame alarm (E010)
-
- RESET comes on when there is an alarm that requires the manual reset by the user (flame
lockout for example)
comes on together with the icon
-
In addition, when parameter P3.02 is set to 1 and there is a water pressure transducer present,
the pressure value is displayed when it is greater than 3 bar (pressure too high) or less than
0.6 bar (pressure too low). In these cases, the boiler continues to operate, as these are only
warnings.
The pressure value and the unit of measurement are also displayed at the end of the following
error messages:
ƒ E041
ƒ E040.
Reset function
In order to reset the boiler's operation in the event of a fault, it is necessary to press the RESET
button. At this point, if the correct operating conditions have been restored, the boiler will restart
automatically. There are a maximum of 3 consecutive attempts at a release by the REC10. In
case of all the attempts are exhausted the definitive fault E099 occurs on the display. The boiler
will need to be unlock by cutting off and reconnecting the electrical supply.
b
If the reset attempts do not activate the boiler, contact the Technical Assistance Centre.
Residence 35 KIS
HTG curve (Qn heating)
Portata termica (kW)
Heat output (kW)
Residence 40 KIS
Curva portata termica - giri ventilatore
HTG curve (Qn heating)
4
6
8
10
12
14
16
18
20
Portata termica (kW)
Heat output (kW)
blinks with a frequency of 0.5sec ON and 0.5sec OFF, the
DAY
, except for flame and water alarms.
DAY
22
24
26
28
30
32
34
DAY