Riello RESIDENCE KIS Installer And User Manual page 26

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
RESIDENCE
The purge cycle can be interrupted early by keeping key 2 (the icon RESET comes on).
The purge cycle can also be interrupted, if the boiler is not set to OFF, by a domestic hot water
request.
ƒ Adjust the ambient temperature thermostat to the desired temperature (~20°C) or, if the
system is equipped with a programmable thermostat or timer, ensure that the thermostat or
timer is "active" and set correctly (~20°C)
ƒ Then set the boiler on WINTER or SUMMER depending on the type of operation desired.
ƒ The boiler will start up and continue working until the set temperatures are reached, after
which it will then go back to standby.
8.1
Operating status
For changing the operating status from WINTER to SUMMER to OFF press key 1 until the icon
for the desired function is displayed.
WINTER MODE
ƒ Set the boiler to the WINTER status by pressing key 1 until both the domestic hot water icon
and the heating icon are displayed.
The interface normally displays the delivery temperature unless there is a domestic hot water
request in progress, in which case the domestic hot water temperature is displayed.
ƒ When there is a heat request and the boiler is igniting, the icon "
Heating REQUEST, the radiator icon blinks:
SUMMER MODE
ƒ Set the boiler to the SUMMER status by pressing key 1 until the domestic hot water icon is
displayed.
In this status the boiler activates the traditional function of just domestic hot water, the interface
normally displays the delivery temperature.
In the event of a domestic hot water pick up, the display shows the temperature of the domestic
hot water.
Domestic hot water REQUEST, the tap icon blinks:
OFF
ƒ Set the boiler to the OFF status by pressing key 1 until the central segments are displayed.
26
" appears on the display.
Bar
DAY
8.2
Adjusting the heating water temperature without an outdoor
temperature sensor connected
If there is no outdoor temperature sensor the boiler operates at a fixed point, the HEATING
setpoint in this case can be set on the main page of the screen.
The successive pressing of the key C or D on the main screen displays the current value of the
heating setpoint; the value blinks with a frequency of 0.5 sec ON, 0.5 sec OFF and the icons
and
come on.
+
The successive pressing of the key C or D allows you to set the value of the heating setpoint
within the preset range:
[40°C - 80.5°C] for high temperature systems
[20°C - 45 °C] for low temperature systems
with steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with respect to the operating
range:
- four bars on = max setpoint.
- one bar on = min setpoint
Keeping one of the two keys C or D pressed for longer, the meter increases the speed of advan-
cement modifying the set value.
If no key is pressed for 5sec, the value set is taken as the new heating setpoint and the display
returns to the main page.
8.3
Adjusting the heating water temperature with an outdoor
temperature sensor connected
If an outdoor temperature sensor is installed and thermoregulation is enabled (parameter
P4.18=1), the delivery temperature is automatically selected by the system, which quickly adjusts
the ambient temperature according to the variations in the outdoor temperature.
If you want to change the temperature, raising it or lowering it with respect to that automatically
calculated by the electronic board, it is possible to change the HEATING setpoint selecting the
desired comfort level within the range (-5 - +5).
Note: if an outdoor temperature sensor is connected it is in any event possible to have the boiler
operate at a fixed point by setting the parameter P4.18 = 0 (menu P4).
8.4
Adjusting the domestic hot water temperature
On the main screen, pressing the key A rather than B displays the current domestic hot water
setpoint, the value blinks with a frequency of 0.5 sec ON, 0.5 sec OFF and the icons
come on.
A
+
B
The successive pressing of the keys A or B allows you to set the value of the domestic hot water
setpoint raising or lowering the value within the preset range in steps of 0.5°C.
C
+
D
RESET
MENU
+
RESET
MENU
and

Advertisement