Access to the parameters
Pressing the MENU key for at least 2 sec provides access to the P1 menu, allowing the para-
meters to be programmed.
If the menu is empty, P8.04 is displayed, otherwise the first item in the menu appears.
Access to the TECHNICAL parameters programming menu is password protected; pressing
MENU a second time for at least 2sec, PWD is displayed blinking with a frequency of 0.5sec ON
and 0.5sec OFF for 2sec.
Then <<0000>> is displayed blinking with a frequency of 0.5sec ON and 0.5sec OFF; the icons
,
,
and
come on to allow the password to be entered.
There are two levels of access to the parameters:
- INSTALLER
- SERVICE
(the user level does not require a password).
Set the password supplied by the manufacturer for the desired access level using the button at
the
,
arrows to enter the value.
Press the key A at the
arrow to confirm.
Pressing key B at the
arrow returns you to the previous level, exiting the P1 menu.
it is now possible to navigate the menu using the C and D arrow keys, confirming access to the
sub-menu with arrow key A or else returning to the previous level using arrow key B.
Prolonged pressure at any point of the menu (>2sec) of the
The interface also reverts automatically to the main screen if no key is pressed within 60sec.
4
4.1
First ignition is carried out by competent personnel from an authorised Technical Assistance
Service Riello.
Before starting up the boiler, check:
- that the data of the supply networks (electricity, water, gas) correspond to the label data
- that the extraction pipes of the flue gases and the air suction pipes are working correctly
- that conditions for regular maintenance are guaranteed if the boiler is placed inside or betwe-
- the seal of the fuel adduction system
- that the fuel flow rate corresponds to values required by the boiler
- that the fuel supply system is sized to provide the correct flow rate to the boiler, and that it has
- that the circulator rotates freely because, especially after long periods of inactivity, deposits
4.2
- Position the system's master switch to the "on" position.
If necessary, the interface automatically goes to the clock menu. On the main screen the icons
blinking with a frequency of 0.5 sec ON, 0.5 sec OFF.
To set the time and day follow the following instructions:
ƒ set the hour with the
ƒ set the minutes with the
ƒ set the day of the week with the
ƒ to exit the time programming without saving the modified values just press
NOTE: It is possible to change the TIME and DAY settings also later by accessing the P1.02
parameter in the P1 menu, or by pressing the A+C keys for at least 2sec.
key returns you to the main page.
ƒ If you need to set the language, select the menu P1 and confirm your choice using .
ƒ Use the arrows to display parameter P1.01, then enter the submenu by pressing
ƒ Use the
Each time that the boiler is powered a vent cycle is carried out lasting 4 min.
The display shows the message -AIR lighting up the icon RESET.
COMMISSIONING

Preliminary checks

en items of furniture
all the safety and control devices required by current regulations
and/or debris can prevent free rotation. See the paragraph "3.13 Manual reset of the circu-
lator" .
Programming the boiler
,
,
and
and ENTER come on while 00:00 is displayed with the first two digits
arrows, then confirm with A
and
and
selected blinks, press the menu MENU key at the icon
setting. The clock blinks for 4sec and then returns to the main screen
A
+
and
buttons to set the desired language – see "3.22 Menu structure" . To
confirm your choice, press
Enter
.
arrows, then confirm with A
and
arrows. The segment in line with the day
Enter
to confirm the time and day
.
C
+
RESET
MENU
ENGLISH
.
13

Advertisement

Table of Contents
loading

Table of Contents