Installation of the PV Module Temperature Sensor

The PV Module Temperature Sensor can be taped to the backside of any PV module in the
array, using the supplied Metal Tape.
A metallic or non-metallic conduit or raceway can be used to protect the PV Module
Temperature Sensor cable on its way to the bottom right of the Weather station enclosure.
 Cut the PV Module Temperature Sensor cable to required length, allowing enough
length for the Weather Data Monitor to be flipped back down into its resting
position.
 Split the cable and strip back the first ¼ inch of each conductor.
 The Ambient Temperature Sensor is not polarized. Connect one of the two wires to
the "Temp PV" terminal and the other one to the
 Tug on both wires to ensure tightness of the connection.