Installation of the PV Module Temperature Sensor
The PV Module Temperature Sensor can be taped to the backside of any PV module in the
array, using the supplied Metal Tape.
A metallic or non-metallic conduit or raceway can be used to protect the PV Module
Temperature Sensor cable on its way to the bottom right of the Weather station enclosure.
Cut the PV Module Temperature Sensor cable to required length, allowing enough
length for the Weather Data Monitor to be flipped back down into its resting
position.
Split the cable and strip back the first ¼ inch of each conductor.
The Ambient Temperature Sensor is not polarized. Connect one of the two wires to
the "Temp PV" terminal and the other one to the
Tug on both wires to ensure tightness of the connection.
360 Merrimack Street, Bldg. 9, Lawrence, MA 01843, USA 978.683.9700 f:978.683.9702
"GND"
terminal just below it.
www.solren.com