To Recall Factory Set Force; To Re-Profile The Door; Accessories; Auxiliary Output - B&D Power Drive RDO-1V4 Installation Instructions Manual

Rolling door opener
Hide thumbs Also See for Power Drive RDO-1V4:
Table of Contents

Advertisement

Power Drive & Roll-A-Pro

11.7 To Recall Factory Set Force

T O R E C A L L F A C T O R Y S E T F O R C E
S T E P O N E
Remove controls
cover

12. Accessories

12.1 Auxiliary Output

The auxiliary output can be used to control alarm or
another garage door opener. A valid transmission from the
pre-coded transmitter will cause the auxiliary output to pulse for
approximately 1 (one) second. The maximum DC voltage must
not exceed 35 volts DC. Maximum current must not exceed
80 ma.

12.2 Keyswitch Connection

The RDO-1V4 has the input to connect
bell switch or keyswitch to open or
close the door.
12.3 Remote Aerial
Some sites cause poor radio reception. Particularly problematic areas are those where there is a large amount of
metal, like a steel garage, or an underground car park with large masses of steel reinforced concrete. These issues,
and others, can create reception issues.
Poor radio reception will be noticed by a reduction in the operating range of the transmitters.
You can evaluate whether fitting an external aerial will benefit as follows;
i. Test the maximum operating range of the transmitter with the garage door closed; then
ii. Test the maximum operating range of the transmitter with the garage door open.
If the range improves when the door is open you can install a remote aerial kit to improve reception.
Mount the aerial to a suitable location on the outside of the garage.
Similar to a television aerial, the better the mounting position the better the reception will be. Where possible, mount
the aerial as high as possible, away from masses of metal and in line of sight position, to where you normally use
your transmitter.
®
installation instructions
default
+
will be
recalled
HOLD for 2 sec
RELEASE

11.8 To Re-profile the door

R E - P R O F I L I N G T H E D O O R
Re-pro ling is a simple way of re-learning the travel
tip
characteristics of a previously setup Limit Switch
travel. Re-pro ling is used when travel characteristic
change due to mechanical adjustments.
To initiate a re-pro le: LIMITS must already be set.
S T E P O N E
Remove
controls cover
HOLD
for 6 secs
RELEASE
S T E P T W O
Door will open and close
several times
External device,
Alarm, Door or
Gate opener.
V+
EB1
0V
EB2
0V
OSC
AUX
13
opener
beeps once
S T E P T H R E E
Then re t
controls cover
opener
beeps once
V+
EB1
0V
EB2
0V
OSC
AUX

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Roll-a-pro rdo-1v3

Table of Contents