Digital Loopback Test With Test Pattern Test - Multitech MT64DSU Owner's Manual

Stand-alone integrated data service unit
Table of Contents

Advertisement

MT64DSU Owner's Manual

Digital Loopback Test With Test Pattern Test

This test allows you to test the local MultiDSU64K, the
communications link, and the remote MultiDSU64K. Use the
following steps to perform the Digital Loopback Test with the Pattern
Test.
With this test enabled, the MultiDSU64K sends and detects a
predefined 511-bit pseudo-random test pattern. When an error is
detected by the MultiDSU64K, the CD (Carrier Detect) LED flashes.
1.
Set DIP-Switch #9 on the remote MultiDSU64K to the UP
position.
2.
Set DIP-Switch #10 on the local MultiDSU64K to the DOWN
position.
3.
The test pattern is generated and either detected as a good test
pattern (test patterns match) or as a failed test (test pattern
received does not match the pattern sent).
Figure 3-5. Digital Loopback with Test Pattern Test
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multidsu64k

Table of Contents