  • Page 2 Legal Notices The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or death, significant property damage, or serious physical or environmental damage.
  • Page 3: Table Of Contents

    CONTENTS Contents Chapter 1 – Product Overview ..........................6 Product Overview................................6 Product Build Options ..............................6 Documentation ................................6 Chapter 2 – Mechanical Drawings..........................7 MTSMC-L4x1 ................................. 7 MTSMC-L4x1-U ................................8 Chapter 3 – Specifications............................9 MTSMC-L4xx and MTSMC-L4xx-U Specifications......................9 Underwriters Laboratories, Inc.
  • Page 4 CONTENTS Chapter 5 – Safety Information ..........................19 Handling Precautions ..............................19 Radio Frequency (RF) Safety ............................19 Sécurité relative aux appareils à radiofréquence (RF)....................19 Interference with Pacemakers and Other Medical Devices ..................20 Potential interference ............................... 20 Precautions for pacemaker wearers ........................20 Vehicle Safety................................
  • Page 5 CONTENTS Connection Manager is not working, and a device connected to the computer is not detected......35 Connection Manager displays "Device Error" status for a serial device ..............35 Index..................................36 ® SocketModem Cell MTSMC-L4E1 Device Guide for Europe...
  • Page 6: Chapter 1 - Product Overview

    LTE Cat 4 performance. These quick-to-market communications devices allow developers to add wireless communication to products with a minimum of development time and expense. SocketModem Cell models are based on industry-standard open interfaces and use MultiTech’s Universal Socket design. Product Build Options...
  • Page 7: Chapter 2 - Mechanical Drawings

    MECHANICAL DRAWINGS Chapter 2 – Mechanical Drawings MTSMC-L4x1 ® SocketModem Cell MTSMC-L4E1 Device Guide for Europe...
  • Page 8: Mtsmc-L4X1-U

    MECHANICAL DRAWINGS MTSMC-L4x1-U ® SocketModem Cell MTSMC-L4E1 Device Guide for Europe...
  • Page 9: Chapter 3 - Specifications

    SPECIFICATIONS Chapter 3 – Specifications MTSMC-L4xx and MTSMC-L4xx-U Specifications Category Description General Standards LTE FDD Cat 4, 3GPP release compliant HSPA+ 21/GPRS fallback USB Interface is CDC-ACM compliant TCP/IP Functions FTP, SMTP, SSL, TCP, UDP Frequency Bands 4G: B1, B7, B8, B20, B28A 3G: B1, B3, B8 2G: B3, B8 Speed...
  • Page 10: Underwriters Laboratories, Inc. Required Global Positioning System (Gps) Statement

    SPECIFICATIONS Category Description Point-to-Point messaging Mobile-Terminated SMS Mobile-Originated SMS SMS over IMS Certifications and Compliance EMC and Radio CE Mark, RED (EU) Compliance Safety Compliance IEC 60950-1 2nd ED Carrier Underwriters Laboratories, Inc. Required Global Positioning System (GPS) Statement Note the following information required by Underwriters Laboratories: Underwriters Laboratories, Inc. Underwriters Laboratories Inc.(“UL”) has not tested the performance or reliability of the Global Positioning System (“GPS”) hardware, operating software or other aspects of this product.
  • Page 11: Uart Dc Electrical Characteristics

    SPECIFICATIONS Wait 30 seconds. Power off or disconnect power. Note: If you send AT#SHDN and do not remove power, the radio restarts after 60 seconds. UART DC Electrical Characteristics Units: Volts Applies to the following pins: Signal Name Signal Name -RTS -DSR -RXD...
  • Page 12: Pinout Specifications

    SPECIFICATIONS Signal VIL Min VIL Max VIH Min VIH Max VOL Min VOL Max VOH Min VOH Max Name USB DN -LED LINK 0.45 2.85 Pinout Specifications Signal Name Logic Level Voltage In/Out Description –RESET 3.3 – 5.0 Device reset (active low) USB VBUS 3.3 –...
  • Page 13 SPECIFICATIONS Signal Name Serial Only USB Only USB DP USB DN –RTS –RXD –TXD –RI –DSR –CTS –DCD –DTR –LED LINK ® SocketModem Cell MTSMC-L4E1 Device Guide for Europe...
  • Page 14: Power Measurements

    SPECIFICATIONS Power Measurements Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into your power source when determining product load. Note: The following notes apply to the following tables. Tx Pulse: The average peak current during a GSM850 transmission burst period or HSDPA/LTE connection.
  • Page 15: Mtsmc-L4E1-U Power Draw

    SPECIFICATIONS MTSMC-L4E1-U Power Draw Radio Sleep Mode Cellular (AVG) TX Pulse (AVG) Total Inrush Total Inrush Protocol Connection Measured Peak Current Charge Charge Connection Idle (No Current for LTE or measured in DURATION to Live Data) (Amps) (Amps) at Amplitude MilliCoulombs during Powerup Network...
  • Page 16: Chapter 4 - Antennas

    The antenna must be the same type, with similar performance and in- and out-of-band radiation patterns as the listed antenna. The antenna used must stay below the FCC/IC maximum gain. For our bundles, MultiTech may change antennas over time. The listed antenna(s) is used as a reference or was shipping when this document was last updated.
  • Page 17: Lte Antenna Diversity

    All antennas need to have a minimum flammability rating. Safety requirements depend on your final product. Unless otherwise noted, antennas certified by MultiTech are not approved for outdoor use. Do not extend these antennas outside of any building. Diversity and Power Draw There are no significant power draw differences.
  • Page 18: Oem Integration

    ANTENNAS OEM Integration FCC & IC Information to Consumers The user manual for the consumer must contain the statements required by the following FCC and IC regulations: 47 C.F.R. 15.19(a)(3), 15.21, 15.105 and RSS-Gen Issue 3, Dec 2010; 7.1.2 and 7.1.3 FCC Grant Notes The OEM should follow all the grant notes listed below.
  • Page 19: Chapter 5 - Safety Information

    SAFETY INFORMATION Chapter 5 – Safety Information Handling Precautions To avoid damage due to the accumulation of static charge use proper precautions, such as an ESD strap, when handling any cellular device to avoid exposure to electronic discharge during handling and mounting the device. Radio Frequency (RF) Safety Due to the possibility of radio frequency (RF) interference, it is important that you follow any special regulations regarding the use of radio equipment.
  • Page 20: Interference With Pacemakers And Other Medical Devices

    SAFETY INFORMATION Interference with Pacemakers and Other Medical Devices Potential interference Radio frequency energy (RF) from cellular devices can interact with some electronic devices. This is electromagnetic interference (EMI). The FDA helped develop a detailed test method to measure EMI of implanted cardiac pacemakers and defibrillators from cellular devices.
  • Page 21: User Responsibility

    Do not place the device alongside computer discs, credit or travel cards, or other magnetic media. The information contained on discs or cards may be affected by the device. Using accessories, such as antennas, that MultiTech has not authorized or that are not compliant with MultiTech's accessory specifications may invalidate the warranty.
  • Page 22: Chapter 6 - Regulatory Information

    Council Directive 2014/53/EU on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity. MultiTech declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The declaration of conformity may be requested at https://www.multitech.com/red...
  • Page 23: Chapter 7 - Environmental Notices

    Substances) complements the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase. The WEEE Directive covers all MultiTech products imported into the EU as of August 13, 2005. EU-based manufacturers, distributors, retailers and importers are obliged to finance the costs of recovery from municipal collection points, reuse, and recycling of specified percentages per the WEEE requirements.
  • Page 24: Restriction Of The Use Of Hazardous Substances (Rohs)

    2015/863 of the European Parliament (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment - RoHS 3). These MultiTech products do not contain the following banned chemicals Lead, [Pb] < 1000 PPM Mercury, [Hg] <...
  • Page 25: Information On Hs/Ts Substances According To Chinese Standards

    ENVIRONMENTAL NOTICES Information on HS/TS Substances According to Chinese Standards In accordance with China's Administrative Measures on the Control of Pollution Caused by Electronic Information Products (EIP) # 39, also known as China RoHS, the following information is provided regarding the names and concentration levels of Toxic Substances (TS) or Hazardous Substances (HS) which may be contained in Multi-Tech Systems Inc.
  • Page 26: Information On Hs/Ts Substances According To Chinese Standards (In Chinese)

    ENVIRONMENTAL NOTICES Information on HS/TS Substances According to Chinese Standards (in Chinese) 依 依 照 照 中 中 国 国 标 标 准 准 的 的 有 有 毒 毒 有 有 害 害 物 物 质 质 信 信 息 息 根据中华人民共和国信息产业部...
  • Page 27: Chapter 8 - Labels

    This device is an industry and/or carrier approved modem. In most cases, when integrated and used with an antenna system that was part of the MultiTech modem certification, additional approvals or certifications are not required for the device that you develop as long as the following requirements are met: Model Identification: The MultiTech model identification allows the carrier to verify the modem as one of its approved models.
  • Page 28: Chapter 9 - Using Connection Manager

    Click Connection Manager. Open or unzip the Connection Manager file and run the installer (.msi file). In the MultiTech Connection Manager Setup Wizard, read the end-user license agreement and check I accept the terms in the License Agreement. Click Next to have the installer automatically disable the native WWAN AutoConfig service in Windows.
  • Page 29: Setting Up A Serial Device In Windows Device Manager

    To specify a folder for Connection Manager, use the default folder or click Change to browse to the folder you want to use. Click Install. A separate wizard opens for installing Telit drivers. Some MultiTech devices use embedded modules from Telit Wireless Solutions to provide cellular connectivity; these devices require Telit drivers. Select Complete setup type.
  • Page 30 USING CONNECTION MANAGER In the Add Hardware Wizard: Click Next. Select Install the hardware that I manually select from a list, then click Next. Select Modems, then click Next. Check Don't detect my modem; I will select it from a list, then click Next. Select Standard Modem Types, then select Standard 33600 bps Modem on the right.
  • Page 31: Connecting A Device

    USING CONNECTION MANAGER Connecting a Device Before You Begin Make sure that your device is connected to the computer where Connection Manager is installed. Set up the device in Device Manager. Refer to Setting Up a Serial Device in Windows Device Manager.
  • Page 32: Uninstalling Connection Manager

    The steps above describe how to uninstall Connection Manager using Control Panel. You can also uninstall the application by using the installer file (.msi). Double-click the file, in the MultiTech Connection Manager Setup Wizard, click Next, and then select Remove on the next two pages.
  • Page 33: Connection Manager User Interface

    USING CONNECTION MANAGER Connection Manager User Interface Connection Manager consists of the following tabs: Main Settings Connection Details Terminal Charts Main tab The Main tab displays the following: Status of device connection: Searching, Connecting, Connected, Disconnecting, or Disconnected The action button, which changes according to the current device connection status: Detect, Connect, or Disconnect Signal strength bars and percentage indicator (only when connection to the carrier's network is established) Note:...
  • Page 34: Settings Tab

    USING CONNECTION MANAGER Connection statistics: download and upload speeds, amount of traffic sent and received (only when connection to the carrier's network is established) The keep-alive check status and when the last ping response was received if Enable keep-alive check is checked on the Connection tab.
  • Page 35: Troubleshooting

    USING CONNECTION MANAGER Troubleshooting Serial COM port is not available in the Serial Modem Settings Close Connection Manager and reopen it. Device is not detected ("No Device") After following the steps to activate your device, the Main tab still indicates "No Device." Try the following steps: Click the Settings tab and make sure that the appropriate modem type is selected: USB or Serial.
  • Page 36 INDEX Index activation...............28 antenna .................16 grant notes...............18 cellular devices............16 diversity..............17 AT#SHDN ...............10 GPS ................10 build options ..............6 hazardous substances ...........24 host labeling..............18 Chinese hazardous substances Chinese version............26 English version ............25 interférence des radiofréquences.........19 Connection Manager Charts tab..............33 connecting device to carrier's network ....31 Connection tab............33 KDB 447498 Section 8 ..........18 Details tab ..............33...
  • Page 37 INDEX radio frequency interference........19 troubleshooting RoHS................24 Connection Manager ..........35 safety UL ..................10 RF interference ............19 user responsibility............21 vehicle..............20 shutdown ..............10 specifications..............9 static................19 vehicle safety ..............20 sécurité interférences RF............19 ® SocketModem Cell MTSMC-L4E1 Device Guide for Europe...