Query Minimum Track Rate - Globalstar ST100 User Manual

Hide thumbs Also See for ST100:
Table of Contents

Advertisement

Byte
0
1
2
3 - 4
5 - 6
Response: AA 05 84 <CRC>
Note, if a track mode (0x30, 0x34, or 0x35) is already active, this command will be NAKed if a value of greater than the
track already running is sent.
The purpose of this command is to allow a VAR to limit the minimum track interval that a customer might set so as to
not over-discharge the battery and solar charging system chosen for the particular application.

4.2.2.27 "Query Minimum Track Rate"

Byte
Bits
0 – 7
0
0 – 7
1
0 – 7
2
3 - 4
0-15
Byte
Use or disclosure of data contained on this sheet is subject to the restrictions in the Distribution Statements on the title page of this
06/18/20
Bits
Parameter
0 – 7
Leader
0 – 7
Length
0 – 7
Command Code.
0 - 15
Rate
0 – 15
CRC
Query minimum track rate
Parameter
Leader
Length
Command Code.
CRC
Query minimum track rate response
Bits
Parameter
GLOBALSTAR PROPRIETARY AND CONFIDENTIAL INFORMATION
Subject to Change without Notice
Description
Always a value of 0xAA.
0x07
0x84 = Set minimum track rate command
Rate in minutes, MSB first
Description
Always a value of 0xAA.
0x05
0x85 = "Query minimum track rate"
Will contain the CRC
Description