Set Low Battery Rate" Command - Globalstar ST100 User Manual

Hide thumbs Also See for ST100:
Table of Contents

Advertisement

Byte
Bits
0 – 7
0
0 – 7
1
0 – 7
2
3 - 4
0-15
Byte
0
1
2
3 - 4
5 - 6

4.2.2.30 "Set Low Battery Rate" command

This command sets the rate to drop to in a low battery condition.
If a track mode (by 0x30, 0x34, or 0x35) is already running, this command will be NAKed if the rate is less than the
already running rate.
Sending a 0x30, 0x34, or 0x35 command with a rate greater than the rate specified by this command will cause those
commands to be NAKed).
Use or disclosure of data contained on this sheet is subject to the restrictions in the Distribution Statements on the title page of this
06/18/20
Parameter
Leader
Length
Command Code.
CRC
Suspended state query response
Bits
Parameter
0 – 7
Leader
0 – 7
Length
0 – 7
Command Code.
0 - 7
Mode argument
0 – 15
CRC
GLOBALSTAR PROPRIETARY AND CONFIDENTIAL INFORMATION
Subject to Change without Notice
Description
Always a value of 0xAA.
0x05
0x81 = Suspended state query
Will contain the CRC
Description
Always a value of 0xAA.
0x06
0x81 = Suspended state query
0x00 = Full Suspend stop tracking messages
completely
0x01 = Partial suspend reduce tracking rate to
low battery rate
0x02 = Unsuspend. Track at normal tracking
rate
document.
P a g e | 57

Advertisement

Table of Contents
loading

Table of Contents