Step 2: Set The Channel That You Wish To Perform The Test On; Step 3: Start The Desired Mode; Step 4: Disable The Test Commands; Step 5: Restore The Desired Setup - Globalstar ST100 User Manual

Hide thumbs Also See for ST100:
Table of Contents

Advertisement

5.2.2 Step 2: Set the channel that you wish to perform the test on.

Use the "setup" command for this. Using the configuration application in "advanced" mode:
Tap the "auth" button.
Send the command: "setup <ch> 3 60 120"
Where "<ch> =
o 0 = Channel A
o 1 = Channel B
o 2 = Channel C
o 3 = Channel D

5.2.3 Step 3: Start the desired mode.

Using the configuration application in "advanced" mode:
Tap the "auth" button.
For CW Mode, send the command: "raw aa06fc01"
For Mod Mode, send the command: "raw aa06fc03"
To send a single test packet, send the command: "raw aa06fc02"
When entering each of the commands above, you should see an ACK: "aa05fc" and 2 bytes of CRC
Repeat steps 2 and 3 for the tests you want to perform on each channel.

5.2.4 Step 4: Disable the test commands.

After turning the power off following the last test, use the configuration application in "advanced" mode to do the
following:
Tap the "auth" button
Send the command: "raw aa067600"
Watch for the ACK, which should be "aa0576" and 2 bytes of CRC

5.2.5 Step 5: Restore the desired setup.

Tap the "auth" button.
Send the command: "setup <ch> <transmit attempts> <min time between attempts> <max time between
attempts>"
Note: Factory default settings are: "setup 0 3 60 120"
Use or disclosure of data contained on this sheet is subject to the restrictions in the Distribution Statements on the title page of this
06/18/20
GLOBALSTAR PROPRIETARY AND CONFIDENTIAL INFORMATION
document.
Subject to Change without Notice
P a g e | 78