Byte
Bits
0 – 7
0
0 – 7
1
0 – 7
2
3 -4
0 - 15
5
0 - 7
6
0 - 7
7
0 - 7
8-9
0 - 15

4.2.2.16 "Update Proprietary Track Data" command

This command is used to change the user programmable data in a proprietary track message. If a proprietary track
session is not in progress, it is ACK'd but will do nothing.
Byte
0
1
2
3
4
5
6-7
Use or disclosure of data contained on this sheet is subject to the restrictions in the Distribution Statements on the title page of this
06/18/20
Parameter
Leader
Length
Command Code.
Interval
Byte 0 value
Byte 7 value
Byte 8 value
CRC
Update proprietary track data command format
Bits
Parameter
0 – 7
Leader
0 – 7
Length
0 – 7
Command Code.
0 – 7
Byte 0 value
0 – 7
Byte 7 value
0 – 7
Byte 8 value
0 – 15
CRC
GLOBALSTAR PROPRIETARY AND CONFIDENTIAL INFORMATION
Subject to Change without Notice
Description
Always a value of 0xAA.
0x0A (10 decimal)
0x35 = Initiate proprietary dock mode track.
Interval in minutes between the track points. 2 to
65535 minutes. (A setting of 2 actually results in a 2.5
minute interval, any other value results in an interval
of that many minutes).
The value to transmit as byte 0
The value to transmit as byte 7.
The value to transmit as byte 8.
Description
Always a value of 0xAA.
0x08
0x31 = Update proprietary track.
The value to transmit as byte 0
The value to transmit as byte 7.
The value to transmit as byte 8.