Byte
Bits
0 – 7
0
0 – 7
1
0 – 7
2
3
0 - 7
4
0 - 7
5
0 - 7
6
0 - 7
7
0 - 7
8-9
0 - 15
4.2.2.26 "Set Minimum Track Rate" command
This command sets the minimum track rate that is allowed to be set with a Proprietary Track (0x30), Motion Activated
Proprietary Track (0x34) or Proprietary Dock Mode (0x35).
The minimum track that can be set in any case with one of the above commands is "2" which is interpreted as 2.5
minutes (all other values that may be sent are interpreted as the actual number of minutes).
This command will not be NAKed for values < 2 but setting this "minimum" value to less than 2 shall simply enforce the
absolute minimum of 2.
The factory value for this shall be "0".
Use or disclosure of data contained on this sheet is subject to the restrictions in the Distribution Statements on the title page of this
06/18/20
Parameter
Description
Leader
Always a value of 0xAA.
Length
0x0A (10 decimal)
Command Code.
0x71 = Query Lifetime Status
Programmed
The number of months for which the device was
lifetime
originally programmed.
Contains the month of the expiration date. If this field
contains 0xFF, this indicates that the unit has not
End Month
obtained a fix since the lifetime was set, and the end
date has not yet been calculated. (Possible values 1 –
12 decimal).
Day of the month of the expiration date. If this field
contains 0xFF, this indicates that the unit has not
End Day
obtained a fix since the lifetime was set, and the end
date has not yet been calculated. (Possible values, 1
– 31 decimal).
The year of the device expiration. Expressed as years
since 2000. E. g. 2021 is represented by "21"
End year
(decimal). If this field contains 0xFF, this indicates that
the unit has not obtained a fix since the lifetime was
set, and the end date has not yet been calculated.
A non-zero value (typically 0xFF) indicates the device
Alive or Dead
is operational. A value of 0 indicates the device has
expired.
CRC
Will contain the response CRC