The duct system must be installed respecting the following:
1. It is recommended to wear gloves to perform this procedure. Remove the plates closing up the 8" dia.
holes on top of the fireplace. Then, cut and remove the insulation in order to obtain two 8" dia.
openings. Then, remove the plates closing up the 8" dia. holes inside the fireplace.
2. Secure the 6 steel brackets (B) with 6 screws provided (C) on top of the fireplace (3 for each ducting).
Insert the ducting (A) (not provided) into each opening and secure it in place using the steel brackets
(B) installed previously with 6 other self-tapping screws provided (C).
3. Secure the ducting (A) to the 90° elbows (E) with self-tapping screws (3 per elbow). Insert the hot air
outlets (F) in the elbow (E). Set hot air outlets frames behind the non-combustible materiel and secure
__________________________________________________________________________ 63