Osburn MATRIX INBUILT Installation And Operation Manual

Hide thumbs Also See for MATRIX INBUILT:
Table of Contents

Advertisement

Quick Links

INSTALLATION AND OPERATION MANUAL
MATRIX
INBUILT
NEW ZEALAND
38 Harris Road, East Tamaki, Auckland
Ph: 09 274 8265
Email:
sales@glendimplex.co.nz
www.glendimplex.com.au
This manual is available for free download on the manufacturer's web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time to
time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Printed in Canada
Distributed by
Glen Dimplex Australasia
Fax 09 274 8472
READ AND KEEP THIS MANUAL FOR REFERENCE
YOUR OSBURN MATRIX INBUILT
HAS BEEN TESTED WITH OUR
ORIGINAL
OSBURN
ZERO
CLEARANCE
INSTALLATION OF ANY OTHER
ZERO CLEARANCE KIT WILL VOID
YOUR WARRANTY.
AUSTRALIA
Unit 1, 21 Lionel Road
Mount Waverley, Victoria 3149
Ph: 1 300 554 155 Fax 8787 3570
Email:
sales@glendimplex.com.au
www.glendimplex.com.au
MATRIX
KIT.
THE
45642A
12-09-2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MATRIX INBUILT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Osburn MATRIX INBUILT

  • Page 1 INSTALLATION AND OPERATION MANUAL MATRIX INBUILT YOUR OSBURN MATRIX INBUILT HAS BEEN TESTED WITH OUR ORIGINAL OSBURN MATRIX ZERO CLEARANCE KIT. INSTALLATION OF ANY OTHER ZERO CLEARANCE KIT WILL VOID YOUR WARRANTY. Distributed by Glen Dimplex Australasia NEW ZEALAND AUSTRALIA...
  • Page 2 Osburn Matrix Inbuilt Installation and Operation Manual THANK YOU FOR CHOOSING THIS WOOD INBUILT We want to congratulate you on your purchase and wish to help you get maximum satisfaction from your wood inbuilt. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technical specifications regarding installation, operation and maintenance of the model you have chosen.
  • Page 3: Table Of Contents

    Zone Heating and How to Make it Work for You ..............9 The Benefits of Low Emissions and High Efficiency ............... 9 Osburn’s Commitment to You and the Environment ............10 2.4.1 What is Your New Wood inbuilt Made Of? ..............10 Fuel ....................
  • Page 4 Osburn Matrix Inbuilt Installation and Operation Manual Fan Operation ........................20 4.5.1 Building Different Fires for Different Needs ..............20 Maintaining Your Wood Heating System ........23 Wood inbuilt Maintenance ....................23 5.1.1 Cleaning Door Glass ......................23 5.1.2 Door adjustment ......................24 5.1.3...
  • Page 5 Osburn Matrix Inbuilt Installation and Operation Manual Appendix 1: Reversing the Door Opening and Adjusting the Handle ..41 Appendix 2: Installing the Fresh Air Intake Kit (AC01298) ....43 Appendix 3: Faceplate Installation ............44 Appendix 4: Blower Installation ............46 Appendix 5: Installing the Fire Screen (AC01315) .........
  • Page 6: Part A - Operation And Maintenance

    Osburn Matrix Inbuilt Installation and Operation Manual PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 SAFETY INFORMATION 1.1 SUMMARY OF OPERATION AND MAINTENANCE CAUTIONS AND WARNINGS HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT •...
  • Page 7: General Information

    Osburn Matrix Inbuilt Installation and Operation Manual GENERAL INFORMATION 2.1 OSBURN MATRIX SPECIFICATIONS Combustible: Wood Heating capacity* 195 m Maximum average heat output – hardwood (Australia): 11.1 kW Average efficiency – hardwood (Australia): 68 % Average emissions – hardwood (Australia): 1.9 g/kg...
  • Page 8 Osburn Matrix Inbuilt Installation and Operation Manual 8 _______________________________________________________________________________...
  • Page 9: Zone Heating And How To Make It Work For You

    2.2 ZONE HEATING AND HOW TO MAKE IT WORK FOR YOU Your new Osburn Matrix wood inbuilt is a space heater, which means it is intended to heat the area it is installed in, as well as spaces that connect to that area, although to a lower temperature.
  • Page 10: Osburn's Commitment To You And The Environment

    2.4 OSBURN’S COMMITMENT TO YOU AND THE ENVIRONMENT The Osburn team is committed to protecting the environment, so we do everything we can to use only materials in our products that will have no lasting negative impact on the environment.
  • Page 11: Fuel

    Osburn Matrix Inbuilt Installation and Operation Manual 3 FUEL 3.1 MATERIALS THAT SHOULD NOT BE BURNED GARBAGE OF ANY KIND, • COAL OR CHARCOAL, • TREATED, PAINTED OR COATED WOOD, • PLYWOOD OR PARTICLE BOARD, • FINE PAPER, COLORED PAPER OR CARDBOARD, •...
  • Page 12: Piece Size

    Osburn Matrix Inbuilt Installation and Operation Manual The pieces should be a consistent length, with a maximum of 25 mm (1”) variation from piece to piece. 3.2.4 PIECE SIZE Firewood dries more quickly when it is split. Large unsplit rounds can take years to dry enough to burn.
  • Page 13: Judging Firewood Moisture Content

    Osburn Matrix Inbuilt Installation and Operation Manual Installation and Operation Manual Here are some things to consider in estimating drying time: Here are some things to consider in estimating drying time: • firewood takes a long time to dry firewood takes a long time to dry •...
  • Page 14: Manufactured Logs

    Osburn Matrix Inbuilt Installation and Operation Manual 3.3 MANUFACTURED LOGS Do not burn manufactured logs made of wax impregnated sawdust or logs with any chemical additives. Manufactured logs made of 100% compressed sawdust can be burned, but use caution in the number of these logs burned at one time. Start with one manufactured log and see how the wood inbuilt reacts.
  • Page 15: Operating Your Wood Inbuilt

    Osburn Matrix Inbuilt Installation and Operation Manual 4 OPERATING YOUR WOOD INBUILT NEVER OVERFIRE YOUR WOOD INBUILT. IF ANY PART OF THE WOOD INBUILT STARTS TO • GLOW RED, OVER FIRING IS HAPPENING. READJUST THE AIR INTAKE CONTROL AT A LOWER SETTING.
  • Page 16: Lighting Fires

    Osburn Matrix Inbuilt Installation and Operation Manual 4.3 LIGHTING FIRES Each person who heats with wood develops their own favorite way to light fires. Whatever method you choose, your goal should be to get a hot fire burning quickly. A fire that starts fast produces less smoke and deposits less creosote in the flue system.
  • Page 17: Two Parallel Logs

    Osburn Matrix Inbuilt Installation and Operation Manual 4.3.3 TWO PARALLEL LOGS Place two spit logs in the firebox. Place a few sheets of twisted newspaper between the logs. Now place some fine kindling across the two logs and some larger kindling across those, log cabin style.
  • Page 18: Ash Removal

    Osburn Matrix Inbuilt Installation and Operation Manual 4.4.2 ASH REMOVAL Ash should be removed from the firebox every two or three days of full time heating. Do not let the ash build up in the firebox because it will interfere with proper fire management.
  • Page 19: Firing Each New Load Hot

    Osburn Matrix Inbuilt Installation and Operation Manual 4.4.4 FIRING EACH NEW LOAD HOT Place the new load of wood on and behind the charcoal and not too close to the glass. Close the door and open the air control fully. Leave the air control fully open until the firebox is full of flames, the wood has charred to black and its edges are glowing red.
  • Page 20: Fan Operation

    Osburn Matrix Inbuilt Installation and Operation Manual 4.5 FAN OPERATION Allow the wood inbuilt to reach operating temperature (approximately one hour), before turning on the fan, since increased airflow from the fan will remove heat and affect the start-up combustion efficiency.
  • Page 21 Osburn Matrix Inbuilt Installation and Operation Manual 4.5.1.2 Long Lasting Low Output Fires Sometimes you will want to build a fire to last up to eight hours, but don’t need intense heat. In this case use smaller pieces of hardwood and place the logs compactly in the firebox so the pieces are packed tightly together.
  • Page 22 Osburn Matrix Inbuilt Installation and Operation Manual The table below provides a very general indication of the maximum burn cycle times you are likely to experience, based on firebox volume. MAXIMUM FIREBOX VOLUME BURN TIME < 0.042 cubic meter 3 to 5 hours 0.042 m...
  • Page 23: Maintaining Your Wood Heating System

    Osburn Matrix Inbuilt Installation and Operation Manual 5 MAINTAINING YOUR WOOD HEATING SYSTEM 5.1 WOOD INBUILT MAINTENANCE Your new wood inbuilt will give many years of reliable service if you use and maintain it correctly. Some of the internal components of the firebox, such as firebricks, baffles and air tubes, will wear over time under intense heat.
  • Page 24: Door Adjustment

    Osburn Matrix Inbuilt Installation and Operation Manual 5.1.2 DOOR ADJUSTMENT In order for your wood inbuilt to burn at its best efficiency, the door must provide a perfect seal with the firebox. Therefore, the gasket should be inspected periodically making sure to obtain an air tight fit.
  • Page 25: Replacing The Door Gasket

    Osburn Matrix Inbuilt Installation and Operation Manual 5.1.3 REPLACING THE DOOR GASKET It is important to maintain the gasket in good condition. After a year or more of use, the door gasket will compress and become hard, which may allow air to leak past it. You can test the condition of the door gasket by closing and latching the door on a strip of paper.
  • Page 26: Cleaning And Painting The Wood Inbuilt

    Osburn Matrix Inbuilt Installation and Operation Manual The gasket must be centered on the edge of the glass. To do this easily, peel back a section of the paper covering the adhesive and place the gasket on a table with the adhesive side up. Stick the end of the gasket to the middle of one edge, then press the edge of the glass down onto the gasket, taking care that it is perfectly centered on the gasket.
  • Page 27: How Often Should You Clean The Flue System

    Osburn Matrix Inbuilt Installation and Operation Manual is mostly clear, creosote builds up more slowly. Your new wood inbuilt has the right characteristics to help you to burn clean fires with little or no smoke, resulting in less creosote in the flue system.
  • Page 28: Part B - Installation

    The Matrix inbuilt can only be installed with the Osburn Matrix zero-clearance kit (sold separately). See installation instructions provided with the kit.
  • Page 29: Safety Information

    Osburn Matrix Inbuilt Installation and Operation Manual 7 SAFETY INFORMATION 7.1 SUMMARY OF INSTALLATION CAUTIONS AND WARNINGS DISCONNECT THE FAN’S ELECTRIC POWER BEFORE SERVICING. • THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE • ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES).
  • Page 30: Regulations Covering Wood Inbuilt Installation

    Osburn Matrix Inbuilt Installation and Operation Manual 7.2 REGULATIONS COVERING WOOD INBUILT INSTALLATION IT IS RECOMMENDED THAT THE INSTALLATION OF YOUR OSBURN WOOD INBUILT BE CARRIED OUT BY A QUALIFIED SPECIALIST INSTALLER. IF ANY ELECTRICAL WORK IS REQUIRED, IT MUST BE CARRIED OUT BY A LICENSED ELECTRICIAN.
  • Page 31: Clearances To Heat-Sensitive Materials

    Osburn Matrix Inbuilt Installation and Operation Manual 8 CLEARANCES TO HEAT-SENSITIVE MATERIALS The clearances shown in this section have been determined by test according to procedures set out in safety standards AS/NZS 2918:2001 When the wood inbuilt is installed so that its surfaces are at or beyond the minimum clearances specified, combustible surfaces will not overheat under normal and even abnormal operating conditions.
  • Page 32 Osburn Matrix Inbuilt Installation and Operation Manual If non-combustible material floor protection needs to be added in front of the hearth extension of the masonry fireplace, it must be made of cement sheet or similar material with a thermal conductivity of 0,8 m².K/W per 4 mm thick and have a thickness of 24 mm. The floor protection...
  • Page 33 Osburn Matrix Inbuilt Installation and Operation Manual Data for Floor Protection Calculation MINIMUM AIR JACKET EXTENDED (Note 1) Flush with Dimension of the MILLIMETRES 500 mm 0 mm D = B - (A - C) fireplace hearth extension facing MAXIMUM...
  • Page 34: Minimum Masonry Opening, Clearances To Combustibles, And Floor Protector

    Osburn Matrix Inbuilt Installation and Operation Manual 8.3 MINIMUM MASONRY OPENING, CLEARANCES TO COMBUSTIBLES, AND FLOOR PROTECTOR 34 ______________________________________________________________________________...
  • Page 35 Osburn Matrix Inbuilt Installation and Operation Manual CLEARANCES MINIMUM MASONRY OPENING 80 mm 1250 mm 622 mm 1340 mm* 781 mm** 439 mm *** MAXIMUM PROTRUSION 30 mm 40 mm 30 mm 40 mm FLOOR PROTECTION 500 mm 975 mm * For a 250 mm mantel shelf.
  • Page 36: The Flue System

    Osburn Matrix Inbuilt Installation and Operation Manual 9 THE FLUE SYSTEM 9.1 GENERAL The flue system, made up of the flue system and the flue between the wood inbuilt and the flue system, acts as the engine that drives your wood heating system. Even the best wood inbuilt will not function safely and efficiently as intended if it is not connected to a suitable flue system.
  • Page 37: Flue Liner Installation

    Osburn Matrix Inbuilt Installation and Operation Manual ATTENTION INSTALLER: When positioning the unit in a fireplace opening prior to the flue installation, install the wood inbuilt into the opening until the top lip of air jacket is flush with fireplace facing.
  • Page 38: If The Flue Liner Does Not Align With The Wood Inbuilt's Flue Outlet

    Osburn Matrix Inbuilt Installation and Operation Manual B) Your dealer may offer a liner fastening system (AC02006), sold separately. Follow the installation instructions provided with the liner fastening system. 9.4.2 IF THE FLUE LINER DOES NOT ALIGN WITH THE WOOD INBUILT’S FLUE OUTLET You can install a liner offset adapter (AC01370), which is sold separately.
  • Page 39: Minimum Flue System Height

    Osburn Matrix Inbuilt Installation and Operation Manual 9.5 MINIMUM FLUE SYSTEM HEIGHT Flue heights and lengths from AS/NZS 2918:2001 The top of the flue system should be tall enough to be above the air turbulence caused when wind blows against the house and its roof.
  • Page 40: The Relationship Between The Flue System And The House

    Osburn Matrix Inbuilt Installation and Operation Manual 9.6 THE RELATIONSHIP BETWEEN THE FLUE SYSTEM AND THE HOUSE Because the flue system is the engine that drives the wood heating system, it must have the right characteristics. The signs of bad system design are cold backdrafting when there is no fire in the wood inbuilt, slow kindling of new fires, and smoke roll-out when the door is opened for loading.
  • Page 41: Appendix 1: Reversing The Door Opening And Adjusting The Handle

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 1: REVERSING THE DOOR OPENING AND ADJUSTING THE HANDLE The Matrix wood inbuilt is equipped with a reversible door in case you prefer a door opening on the other side. Follow the steps below if you wish to avail yourself of this feature: 1.
  • Page 42 Osburn Matrix Inbuilt Installation and Operation Manual 1. To reverse the door handle (E), remove the spring pin (H), the 2 washer (I), and the assembled balled latch cylindrical pin (K). 2. Unscrew the 2 bolts (F) that holds the handle guide (G) in place.
  • Page 43: Appendix 2: Installing The Fresh Air Intake Kit (Ac01298)

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 2: INSTALLING THE FRESH AIR INTAKE KIT (AC01298) Note: Only remove the knock-out that will be connected to the fresh air inlet. To install a fresh air intake kit to the wood inbuilt, the purchase of accessory AC01298 is required.
  • Page 44: Appendix 3: Faceplate Installation

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 3: FACEPLATE INSTALLATION NOTE: If the depth and or the opening of the masonry hearth require the use of the projection AC01323 and or a faceplate backing plate kit AC01322 or AC01332,...
  • Page 45 Osburn Matrix Inbuilt Installation and Operation Manual 3. Align the holes in the support bracket of faceplate (F) then tighten the screws (H) already installed on the wood inbuilt. 4. Align the holes in the support bracket of faceplate (G) then tighten the screws (H) already installed on the wood inbuilt.
  • Page 46: Appendix 4: Blower Installation

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 4: BLOWER INSTALLATION 1. Slightly loosen screws (B). 2. Lift the faceplate (A) by 13 mm (1/2”) then pull it towards you to remove. 3. Slightly loosen the 4 wing nut then...
  • Page 47 Osburn Matrix Inbuilt Installation and Operation Manual ______________________________________________________________________________ 47...
  • Page 48: Appendix 5: Installing The Fire Screen (Ac01315)

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 5: INSTALLING THE FIRE SCREEN (AC01315) Open the door. Hold the fire screen by the two handles and bring it close to the door opening. Lean the upper part of the fire screen...
  • Page 49: Appendix 6: Installation Of Secondary Air Tubes And Baffle

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 6: INSTALLATION OF SECONDARY AIR TUBES AND BAFFLE 1. Starting with the rear tube, lean and insert the right end of the secondary air tube into the rear right channel hole. Then lift and insert the left end of the tube into the rear left channel.
  • Page 50 Osburn Matrix Inbuilt Installation and Operation Manual Note that secondary air tubes (A) can be replaced without removing the baffle board (B). Important Notes: The air tubes are identified for placement as follows: Model Type of tube Matrix wood inbuilt Front►...
  • Page 51: Appendix 7: Removal Instructions

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 7: REMOVAL INSTRUCTIONS For the purpose of inspecting the wood inbuilt itself or the fireplace, your wood inbuilt may need to be removed. To remove your wood inbuilt follow these instructions: • Remove the faceplate assembly (A) using the reverse steps of Appendix 3.
  • Page 52: Appendix 8: Exploded Diagram And Parts List

    Osburn Matrix Inbuilt Installation and Operation Manual APPENDIX 8: EXPLODED DIAGRAM AND PARTS LIST 52 ______________________________________________________________________________...
  • Page 53 Osburn Matrix Inbuilt Installation and Operation Manual IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your wood inbuilt, please provide the model number and the serial number. We reserve the right to change parts due to technology upgrade or availability. Contact an authorized dealer to obtain any of these parts.
  • Page 54 Osburn Matrix Inbuilt Installation and Operation Manual Item Description 35 PL65646 GLASS FRAME 36 PL53585 GLASS RETAINER 19MM X 22MM 37 30124 SCREW #8 - 32 X 5/16'' TRUSS QUADREX ZINC 38 SE45642 INSTRUCTION MANUEL KIT MATRIX WOOD INBUILT 39 30075 BRASS METAL SCREW #6 X 1/2"...
  • Page 55 Osburn Matrix Inbuilt Installation and Operation Manual ______________________________________________________________________________ 55...
  • Page 56 Osburn Matrix Inbuilt Installation and Operation Manual Manufactured by: STOVE BUILDER INTERNATIONAL INC. 250, de Copenhague, Saint-Augustin-de-Desmaures (Quebec), Canada G3A 2H3 Tel: (418) 878-3040 Fax: (418) 878-3001 www.osburn-australia.com Distributed by Glen Dimplex Australasia NEW ZEALAND AUSTRALIA 38 Harris Road, East Tamaki, Auckland...

This manual is also suitable for: