  • Page 1 Wood Insert Owner's Manual Part 2 of 2 INSTALLATION AND OPERATION REQUIREMENTS OSBURN 1700-I (OB01705 Model) Safety tested according to ULC S628, UL 1482 and UL 737 by an accredited laboratory. US Environmental Protection Agency phase II certified wood insert compliant with 2020 cord wood standard.
  • Page 2 It is also highly recommended to register the warranty online at https://www.osburn-mfg.com/en/warranty/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit.
  • Page 3: Table Of Contents

    Optional Fresh Air Intake Kit Installation...............23 Optional Fire Screen Installation ..................24 Log Retainers Installation ...................26 Air Tubes and Baffle Installation ..................27 Removal Instructions ....................30 Exploded Diagram and Parts List ................31 DROLET LIMITED LIFETIME WARRANTY ................. 34 Product Specification Manual - Osburn 1700-I Page 3...
  • Page 4: Certification Plate

    1. CERTIFICATION PLATE Page 4 Product Specification Manual - Osburn 1700-I...
  • Page 5: General Information

    This appliance is officially tested and certified by an independent agency. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17. Based on EPA letter dated November 1, 2022. Carbon monoxide. Product Specification Manual - Osburn 1700-I Page 5...
  • Page 6: Specifications

    CAN/CSAZ240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17. Based on EPA letter dated November 1, 2022. Page 6 Product Specification Manual - Osburn 1700-I...
  • Page 7: Dimensions

    15 3/4" 399mm 24 3/8" 6 5/8" 620mm 169mm 16 1/2" 419mm 17 5/8" 446mm 22 3/8" 569mm Figure 3 : Front View Figure 4 : Side View - Maximum Insert Projection Product Specification Manual - Osburn 1700-I Page 7...
  • Page 8 Figure 5 : Door Opening 3/16" 5/16" 19 5/8" 11 7/8" 498mm 301mm 13 1/2" 343mm Figure 6 : Front View - Combustion Chamber Figure 7 : Side View - Combustion Chamber Page 8 Product Specification Manual - Osburn 1700-I...
  • Page 9 The front (3rd) piece should stand off on the steel andirons by approximately 1-2 inches. The 2 other pieces should be added on top of the first Product Specification Manual - Osburn 1700-I Page 9...
  • Page 10 4 inches cross section dimensions approximately) on top. To make sure combustion is equal, put the smallest piece on top of the first three, at the back of the firebox (see Figure 16 for an example of low burn load). Page 10 Product Specification Manual - Osburn 1700-I...
  • Page 11 For optimal medium fire load, use medium to large size fuel pieces (between 4- and 5.5-inches cross section dimensions approximately) on the bottom and use small to medium size fuel pieces (2.5 to 4 inches cross section dimensions approximately) on top. To make sure combustion is Product Specification Manual - Osburn 1700-I Page 11...
  • Page 12 4 and 15 minutes after the loading period. Before closing further, make sure the flame intensity is increasing or stable. Turn ON the blower at maximum speed. Page 12 Product Specification Manual - Osburn 1700-I...
  • Page 13: Clearances To Combustible Material

    27 ½" (700 mm) 12 ⅞ (328 mm) If a fresh air intake is required, it is recommended to add at least 4" to the width of the minimum opening of the hearth. Product Specification Manual - Osburn 1700-I Page 13...
  • Page 14: Floor Protection

    (406 mm USA) and at least 18" (457 mm Canada) without an R value. If the hearth elevation is lower than 5" (127 mm), the non-combustible (B) floor protection in front of the insert should have an R value equal or greater than 1.00 and shall extend 23" (584 mm) in front of the unit. Page 14 Product Specification Manual - Osburn 1700-I...
  • Page 15: R Value

    0.51 Hardibacker® 500 0.44 Wonderboard® 3.23 0.31 Cement mortar 5.00 Common brick 5.00 Face brick 9.00 0.11 Marble 14.3 – 20.00 0.07 – 0.05 Information as reported by manufacturers and other resources. Product Specification Manual - Osburn 1700-I Page 15...
  • Page 16 K value = 0.75 Thickness = 1 R value = Thickness/K = 1/0.75 = 1.33 Horizontal still air can’t be «stack» to accumulate R-values; each layer must be separated with another non-combustible material. Page 16 Product Specification Manual - Osburn 1700-I...
  • Page 17: Installing Options On Your Product And Replacing Parts

    Remove the split pin by pulling and turning it using pliers. Turn the handle one counterclockwise turn to increase pressure. Reinstall the split pin with a small hammer. Figure 20 : Removing the split pin Figure 21 : Installing the split pin Product Specification Manual - Osburn 1700-I Page 17...
  • Page 18 Using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions. Configurations 1-2-3-4-5-6, show in which direction these act on the adjustment of the door. Page 18 Product Specification Manual - Osburn 1700-I...
  • Page 19 (see procedure below). Reinstall the glass, being careful to centre the glass in the door and not to over-tightening the retaining screw. Figure 22 : Replacing the glass Product Specification Manual - Osburn 1700-I Page 19...
  • Page 20: Blower And Ash Lip Installation

    Blower and Ash Lip Installation Install the ash lip (A) on the insert with Center the blower on the ash lip and push three screws (B). it against the firebox. Then push it until it clips. Page 20 Product Specification Manual - Osburn 1700-I...
  • Page 21 Position the overlay (C) on the door frame and secure it in place from behind using the screws (D). To ease the installation, do not tighten the screws until they are all installed. Note: It is not necessary to remove the glass to install the overlay. Product Specification Manual - Osburn 1700-I Page 21...
  • Page 22: Faceplate Installation

    Line up the holes of the upper faceplate panel (L) with the holes of the side panels (M) and (N). Secure them together using four bolts (O) and nuts (P) provided. DETAIL A Page 22 Product Specification Manual - Osburn 1700-I...
  • Page 23 (W) down over the faceplate. between the inner edge of the trim and the front of the faceplate. Product Specification Manual - Osburn 1700-I Page 23...
  • Page 24 Align the holes in the faceplate extension (X) with the holes in each faceplate side panels. Secure both assemblies together using 6 bolts (Y) and nuts (Z) provided. Page 24 Product Specification Manual - Osburn 1700-I...
  • Page 25 (BB). Then push towards the fireplace. 11. Once the faceplate is in place, secure the assembly by tightening nuts (AA) using a 7/16" (11 mm) open end wrench. Product Specification Manual - Osburn 1700-I Page 25...
  • Page 26: Optional Fresh Air Intake Kit Installation

    Install the plate (K) with four screws (L) on the unused side of the insert. he pipe must be HVAC type, insulated, and must comply with ULC S110 and/or UL 181, Class 0 or Class 1. Page 26 Product Specification Manual - Osburn 1700-I...
  • Page 27: Optional Fire Screen Installation

    In the United States or in provinces with a particulate emissions limit (e.g.: US EPA), the use of open- door wood stoves with a rigid firescreen is prohibited. Open the door. Hold the fire screen by the two handles and bring it close to the door opening. Product Specification Manual - Osburn 1700-I Page 27...
  • Page 28 Lift the fire screen upwards and push the bottom part towards the insert then let the fire screen rest on the bottom of the door opening. Warning: Never leave the insert unattended while in use with the fire screen. Page 28 Product Specification Manual - Osburn 1700-I...
  • Page 29: Log Retainers Installation

    Log Retainers Installation Product Specification Manual - Osburn 1700-I Page 29...
  • Page 30: Air Tubes And Baffle Installation

    To remove the tubes use the above steps in reverse order. Note that secondary air tubes (A) can be replaced without removing the baffle board (B) and that all tubes are identical. Page 30 Product Specification Manual - Osburn 1700-I...
  • Page 31 Product Specification Manual - Osburn 1700-I Page 31...
  • Page 32: Removal Instructions

    Remove faceplate (B) by pulling on it. Remove the blower assembly (A). Remove the three screws securing the pipe connector (D). Unscrew the bolts securing the insert to the floor on each side of the unit (E). Page 32 Product Specification Manual - Osburn 1700-I...
  • Page 33: Exploded Diagram And Parts List

    4.10 Exploded Diagram and Parts List 25 41 DETAIL A FITS FOR S.N: 2230 + 15 16 APPLICABLE AUX N.S: 2230 + FITS FOR S.N: 2230 + APPLICABLE AUX N.S: 2230 + Product Specification Manual - Osburn 1700-I Page 33...
  • Page 34 BLACK LARGE FACEPLATE TRIMS (32" X 50") OA10122 BLACK FACEPLATE TRIMS (29" X 44") OA10117 LARGE FACEPLATE (32" X 50") PL70673 FACEPLATE TOP PANEL 30 X 50 PL70674 FACEPLATE SIDE PANEL 30 X 50 Page 34 Product Specification Manual - Osburn 1700-I...
  • Page 35 RHEOSTAT NUT 44080 RHEOSTAT WITHOUT NUT (MODEL KBMS-13BV) SE75109 BLOWER ASSEMBLY SE45981 OSBURN 1700 INSERT INSTRUCTIONS MANUAL KIT AC05959 METALLIC BLACK STOVE PAINT - 342 g (12oz) AEROSOL SE74167 DOOR HINGE REPLACEMENT KIT Product Specification Manual - Osburn 1700-I Page 35...
  • Page 36 Labour cost and repair work to the account of the manufacturer are based on a predetermined rate schedule and must not exceed the wholesale price of the replacement part. Shall your unit or a components be defective, contact immediately your OSBURN dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling: •...
  • Page 37 Product Specification Manual - Osburn 1700-I Page 37...
  • Page 38 Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 1-877-356-6663 of information contained in any document obtained from www.osburn-mfg.com/en unauthorized sources. tech@sbi-international.com...

This manual is also suitable for: