AMT58x-PB Profibus®

6.4 DDLM_Set_Prm

When system is turned on, configuration data set by the operator is
sent to the absolute encoder by the controller. Parameters
transmission depends on the configuration chosen by the operator.
Customarily data is sent automatically while data setting is carried
out through a user's interface available in the controller's software
(for instance, STEP7, see section "5.1 STEP7 configuration")
However sometimes it is necessary to set some bits and bytes
according to the working specifications you want to set.
Data transmission is carried out in compliance with values set for the
encoder profile and shown in the following tables.
DDLM_Set_Prm with Class 1:
Byte
0...9
10
11...20
DDLM_Set_Prm with Class 2:
Byte
0...9
10
11...14
15...18
19...20
22
Reserved for PROFIBUS network
Operating parameters
bit 0
bit 1
Class 2 functionality
bits2...5
bit 6
bit 7
Reserved for PROFIBUS network
Operating parameters
bit 0
bit 1
Class 2 functionality
bit 2
bit 3
Scaling function control
bits 4, 5
bit 6
bit 7
Counts per revolution
Total resolution
Parameter
Code sequence
Reserved
Diagnostic type
Exchange type
Reserved
Parameter
Code sequence
Reserved
Reserved
Diagnostic type
Exchange type
Reserved