Technical specifications
* Other pressures available on request
** Other voltages on request
* At lower pressures, the machine should be supplemented with a break tank
* Including packaging
** Delivery in 2 parts. If necessary, delivered in smaller components.
CONNECTION, STEAM-HEATED MACHINE 150–250 kPa *
Total connected load (kW)
Main fuse 400-415 V 3N~(A) **
Max. connection area 400-415V 3N~ (L1-L3, N, PE) (TN-S) Cu (mm²)
Maximum short-circuit current Icu (kA)
Steam connection (internal thread)
Condensing water connection (internal thread)
WATER, DRAIN AND VENTILATION CONNECTIONS
Water quality, hardness (° dH)
Cold water connection 5-12° C (internal thread)
Hot water connection 50-65° C (internal thread)
Compressed air 600kPa (internal thread)
Waste pipe connection, PP pipe (ø mm)
Water capacity, cold water, pressure (kPa) *
Water capacity, cold water, flow (litres/minute)
Water capacity, hot water, min./max. pressure (kPa)
Floor drain, capacity (litres/sec.)
Ventilation, connection (ø mm)
Heat load to room, latent / sensible / total (kW)
SIZE AND WEIGHT FOR TRANSPORT *
Overall machine size (LxWxH) (m)
Overall machine weight (kg)
Size part 1 (LxWxH) (m) **
Size part 2 (LxWxH) (m) **
Weight part 1 (kg) **
Weight part 2 (kg) **
WD-18CW
49
Rev. (202211)
4.5
20
35
10
R1¼"
R¾"
2–7
R¾"
R¾"
50
300
30
100 / 600
3
160
4.5 / 6.5 / 11
2.6 x 2.0 x 2.75
1350
2.6 x 2.0 x 2.25
2.2 x 2.0 x 0.8
850
580