Setting
2.2.7
EF_MV (Function ID:441081)
Setting items
EF1-EN
EF2-EN
EF3-EN
EF4-EN
EF1
EF1-Dir
Fwd/
EF1-Angle
Rev
EF1-Vpol
EF1-Timer
DT
EF1
EF1-DPR
TEF1
IEC
EF1
EF1-DPR
EF1-TMS-IEC
TEF1R
UK
EF1
EF1-DPR
EF1-TMS-UK
TEF1R
IEEE
EF1
EF1-DPR
EF1-TMS-
IEEE
EF1-Rtimer
TEF1R
EF1-RTMS-
IEEE
US
EF1
EF1-DPR
EF1-TMS-US
EF4-Rtimer
TEF1R
EF1-RTMS-US
ORG
EF1
EF1-DPR
EF1-TMS-ORG
EF1-Rtimer
TEF1R
EF1-RTMS-
ORG
EF1-k
EF1-a
EF1-c
EF1-kr
EF1-b
Output
EF1-VTFBlk
Range
Unit
Off / On
- EF1 protection scheme switch
Off / On
- EF2 protection scheme switch
Off / On
- EF3 protection scheme switch
Off / On
- EF4 protection scheme switch
NonDir / Forward /
- EF1 directional characteristic
Reverse
-90 - 90
deg EF1 directional characteristic angle
0.5 - 100.0
V EF1 polarizing voltage level
DT / IEC-NI / IEC-VI /
IEC-EI / UK-LTI /
IEEE-MI / IEEE-VI /
- EF1 delay type
IEEE-EI / US-CO2 /
US-CO8 / Original
0.02 - 150.00
A EF1 threshold (in DT mode)
10 - 100
% EF1 drop-out/pick-up ratio
0.00 - 300.00
s EF1 operating delay time (in DT mode)
0.02 - 25.00
A EF1 threshold (in IDMT mode)
10 - 100
% EF1 drop-out/pick-up ratio
0.010 - 50.000
- EF1 time multiplier of IEC inverse curve
0.00 - 300.00
s EF1 definite time reset delay
0.02 - 25.00
A EF1 threshold (in IDMT mode)
10 - 100
% EF1 drop-out/pick-up ratio
0.010 - 50.000
- EF1 time multiplier of UK inverse curve
0.00 - 300.00
s EF1 definite time reset delay
0.02 - 25.00
A EF1 threshold (in IDMT mode)
10 - 100
% EF1 drop-out/pick-up ratio
0.010 - 50.000
- EF1 time multiplier of IEEE inverse curve
DEF / DEP
- EF1 reset delay type of IEEE
0.00 - 300.00
s EF1 definite time reset delay
EF1 dependent reset time multiplier of IEEE
0.010 - 50.000
-
inverse curve
0.02 - 25.00
A EF1 threshold (in IDMT mode)
10 - 100
% EF1 drop-out/pick-up ratio
0.010 - 50.000
- EF1 time multiplier of US inverse curve
DEF / DEP
- EF1 reset delay type of US
0.00 - 300.00
s EF1 definite time reset delay
EF1 dependent reset time multiplier of US
0.010 - 50.000
-
inverse curve
0.02 - 25.00
A EF1 threshold (in IDMT mode)
10 - 100
% EF1 drop-out/pick-up ratio
0.010 - 50.000
- EF1 time multiplier of Original inverse curve
DEF / DEP
- EF1 reset delay type of ORG
0.00 - 300.00
s EF1 definite time reset delay
EF1 dependent reset time multiplier of
0.010 - 50.000
-
Original inverse curve
0.00000 - 500.00000
- EF1 user original curve coefficient
0.00000 - 10.00000
- EF1 user original curve coefficient
0.00000 - 10.00000
- EF1 user original curve coefficient
0.00000 - 500.00000
- EF1 user original curve coefficient
0.00000 - 10.00000
- EF1 user original curve coefficient
Non / Block
- EF1 operation block by VTF
- 52 -
Contents
6F2T0200 (0.15)
Default
Note
Off
Off
Off
Off
NonDir
-45
3.0
DT
0.30
100
1.00
0.30
100
1.000
0.00
0.30
100
1.000
0.00
0.30
100
1.000
DEF
0.00
1.000
0.30.
100
1.000
DEF
0.00
1.000
0.30
100
1.000
DEF
0.00
1.000
0.00000
0.00000
0.00000
0.00000
0.00000
Non