11.3.11 Signal (Data ID)
Monitoring point (for Editio1 and Editon2)
◆
61850 (Function ID: 301001)
Element ID
0010001001
3100001440
3100011440
3100021440
3100031440
3100041440
3100051440
3100001441
3100011441
3100021441
3100031441
3100041441
3100051441
3100001001
3100011001
3100021001
3100031001
3100041001
3100051001
3110041005
Monitoring point (for Editio1 and Editon2)
◆
GOOSE (Function ID: 301101)
Element ID
3110001001
Note: See page 598 for bare goose output signals (i.e., SUB_QUAL# signals).
Monitoring point (for Edition 2)
◆
GOOSEed2 (Function ID: 305101)
Element ID
7400006470
7400016470
7400026470
7400036470
7400046470
7400056470
7400066470
7400076470
7400086470
7400096470
74000A6470
Name
61850STAT
INCOMINGPKT#0
INCOMINGPKT#1
INCOMINGPKT#2
INCOMINGPKT#3
INCOMINGPKT#4
INCOMINGPKT#5
OUTGOINGPKT#0
OUTGOINGPKT#1
OUTGOINGPKT#2
OUTGOINGPKT#3
OUTGOINGPKT#4
OUTGOINGPKT#5
REMOTEPORTNUM#0
REMOTEPORTNUM#1
REMOTEPORTNUM#2
REMOTEPORTNUM#3
REMOTEPORTNUM#4
REMOTEPORTNUM#5
Qual_Validity
Name
GOOSESUB_STATUS
Name
SUB_GOOSE_MONITOR#0
SUB_GOOSE_MONITOR#1
SUB_GOOSE_MONITOR#2
SUB_GOOSE_MONITOR#3
SUB_GOOSE_MONITOR#4
SUB_GOOSE_MONITOR#5
SUB_GOOSE_MONITOR#6
SUB_GOOSE_MONITOR#7
SUB_GOOSE_MONITOR#8
SUB_GOOSE_MONITOR#9
SUB_GOOSE_MONITOR#10
- 786 -
Description
Status of IEC 61850(T:Running, F:Stop)
Incoming packet number from IEC 61850 client#0
Incoming packet number from IEC 61850 client#1
Incoming packet number from IEC 61850 client#2
Incoming packet number from IEC 61850 client#3
Incoming packet number from IEC 61850 client#4
Incoming packet number from IEC 61850 client#5
Outgoing packet number to IEC 61850 client#0
Outgoing packet number to IEC 61850 client#1
Outgoing packet number to IEC 61850 client#2
Outgoing packet number to IEC 61850 client#3
Outgoing packet number to IEC 61850 client#4
Outgoing packet number to IEC 61850 client#5
Port number of IEC 61850 client #0
Port number of IEC 61850 client #1
Port number of IEC 61850 client #2
Port number of IEC 61850 client #3
Port number of IEC 61850 client #4
Port number of IEC 61850 client #5
IEC 61850 validity of quality
Description
0 if all GOOSE being subscribed are not subscribed.
Description
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
Monitor/Diagnose GOOSE Message
6F2T0200 (0.15)
GRE200 (1,2)