10. EXTERNAL CONNECTIVITY. (Fig.27)

10.1.

Solar photovoltaic integration

Main components of the system are:
Pos.
1
2
3
An on/off signal should be transmited by wire, from PV system's control unit to the main PCB of the heat pump water heater. The wire
should be connected to free contacts, designated by "PV" (Fig.23), located on the main PCB.
Once the heat pump detects the signal from PV, the heat pump or e-heater will be driven by solar PV, and the heat pump will also make
the water setting temperature higher to have more hot water.
PV contact (Fig.23) should be connected to the PV system. The logic of PV function is as follow:
When parameter 17 = 1, PV function is available.
When PV contacts are open, water tank set temp(parameter 00) is valid;
When PV contacts are closed then water tank set temp (parameter 00) is valid and Parameter 00=65°C (max).
WARNING!

11. MAINTENANCE AND CLEANING.

WARNING!
in serious danger. If your equipment needs to be repaired, please contact the technical assistance service.
WARNING!
ly connected to the power supply. Therefore, disconnect the equipment from the mains power supply before carrying out any
maintenance or cleaning activities.
11.1.

Resetting of safety thermostat 34 (Fig.9)

The device is equipped with a safety thermostat. When manually reset, the equipment is tripped in case of over-heating.
In order to reset the protection, it is necessary to:
Disconnect the device from the mains power supply;
Remove the plastic cover 35 by undoing the appropriate locking screws;
Manually reset the safety thermostat 34 (Fig. 9).
Reassemble the plastic cover 35 that was previously removed
WARNING!
absence of water inside the tank.
WARNING!
of the equipment. Substitute the faulty elements only with original spare parts.
N.B.: The intervention of the thermostat excludes the operation of the electric heating elements but not the heat
pump system within the permitted operating limits.
Description
Photovoltaic panel
Invertor DC to AC
Control unit of PV system
Only qualified persons should design and install photovoltaic system!
Any equipment repair must be performed by qualified personnel. Improper repairs can put the user
Before attempting any maintenance operation, make sure that the equipment is not and cannot be accidental-
The tripping of the safety thermostat can be caused by a fault linked to the control board or by the
Carrying out repair operations on parts that perform safety functions jeopardises the safe operation
Pos.
4
5
6
23
Description
Main PCB of the appliance
Main electric supply
Relay, normally open

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquathermica compact hpwh 3.2 150

Table of Contents