Condense Drain Connections; Electrical Connections; Commissioning; Filling The Tank With Water - TESY AquaThermica Compact HPWH 3.2 100 Installation And Maintenance Manual

Domestic hot water heat pump
Hide thumbs Also See for AquaThermica Compact HPWH 3.2 100:
Table of Contents

Advertisement

Available languages

Available languages

6.5.

Condense drain connections.

Condensate, that forms during the operation of the heat pump, flows through an appropriate discharge pipe (Ø20mm) that
passes inside cladding and it comes out on the side of the equipment. Use flexible hose Ø20 (Fig. 21). Connect the hose to a siphon
so that the condensate can flow freely.
6.6.

Electrical connections

The device is supplied already wired for the main power supply. It is powered through a flexible cable and a socket/plug combina-
tion. An earthed Schuko socket with separate
protection is needed for the connection to the mains power supply.
WARNING!
The power supply to which the equipment will be connected must be protected by an adequate residual current
circuit breaker at least: 16A/230V
The type of residual current circuit breaker must be chosen by evaluating the type of electric equipment to be used
on the entire system.
With reference to the connection to the main power supply and the safety equipment (e.g. residual current circuit
breaker) comply with standard IEC 60364-4-41.

7. COMMISSIONING.

WARNING!
Check that the equipment is connected to the earth cable.
• Check that the line voltage corresponds to that indicated on the equipment identification plate.
• Do not exceed the maximum permitted pressure indicated in the "general technical data" section; 8 Bar
Check that the water circuit safety valve is working
7.1.

Filling the tank with water.

The commissioning procedure must be carried out by performing the following procedures:
Fill the boiler by opening inlet tap No5 (Fig. 20) and the tap hot water of your bathroom.
The tank is fully filled with water, when only water without air starts leaking trough the
tap in the bathroom. Check that there are no leaks from gaskets and connections.
Tighten the bolts or connections where necessary;

8. OPERATING MODES. USER INTERFACE. INITIAL CONTROLLER ADJUSTMENT.

8.1.
User interface – Buttons and their function explanation.
8.1.1.

Power 'ON'

When the unit is connected to the main power supply, all icons are displayed on the controller screen for 3 seconds as
picture above.
After functionality check, the unit enters into the "standby" mode (the appliance is still OFF):
8.1.2.

ON/OFF button

Press this button
and hold it for 3 seconds when the unit is in standby, the unit will be turned 'ON'.
and hold it for 3 seconds when the unit is running, the unit will be turned OFF - "Standby".
Press this button
Short press this button to enter or exit the parameter setting or checking.
8.1.3.

UP and DOWN buttons

These are the multi-purpose buttons. They are used for the temp setting, parameter setting, parameter checking, clock adjustment
and adjustment of the timer.
Short press this button to enter or exit the parameter setting or checking.
During running status, press
Press these buttons when the unit is on clock setting status, the hour(s) and the minute(s) of the clock
time can be adjusted.
Press these buttons when the unit is on timer setting status, the hour(s) and the minute(s) of the timer
'ON'/'OFF' can be adjusted.
or
button to adjust the setting temperature directly.
16