Jøtul GF 160 DV Installation And Operation Instruction Manual page 8

Direct vent gas stove
Table of Contents

Advertisement

130112_Rev 2 GF 160 DV 1/22
Alcove Installation
Maximum Alcove Depth:
Minimum Alcove Width*:
Minimum Alcove Ceiling Height
from floor:
* Alcove clearances are determined through testing in specific
construction configurations which often result in greater clearances
than an open stove installation.
Clearance to Combustible Materials Above
Stove
Minimum Mantle Height from floor: 46 3/4"
24" maximum mantle depth.
8
24"
32 1/2"
69"
with
Figure 5.4
Alcove Clearances.
Minimum Ceiling or Alcove Height
11 1/4”
286 mm
46 3/4”
118.74 cm
35 1/2”
902 mm
Figure 5.5. Mantel and Ceiling Clearances.
Max.
Mantle Depth
24”

Advertisement