Jøtul GF 160 DV Installation And Operation Instruction Manual page 10

Direct vent gas stove
Table of Contents

Advertisement

130112_Rev 2 GF 160 DV 1/22
Approved Horizontal and Vertical Vent
Terminations
• ALL VENTING MUST TERMINATE (END)
WITHIN ONE OF THE DESIGNATED AREAS.
• SET STOVE EXHAUST RESTRICTOR TO THE
POSITION THAT CORRESPONDS TO THE
VENT TERMINATION AREA IN THE MATRIX.
When termination is exactly on a division line,
use the less restrictive position. For example,
if termination is 10 feet high and offset 7 feet,
restriction should be set at Position B.
• Up to two 45° elbows or one additional 90° elbow is
permitted in addition to the first elbow, however, a 5
foot reduction in horizontal length must be made for
each additional elbow whether 45° or 90°.
Remove Collar Grills
Figure 6.3.
Use a 10 mm wrench to loosen the Restrictor lock nut.
10
35 ft.
(10.67 m)
D
15 ft.
(4.57 m)
C
10 ft.
(3.05 m)
B
6 ft.
(183 cm)
Min.
A
Vertical
Termination
2 ft.
(61cm)
5 ft.
(152cm)
H O R I Z O N TA L R U N
Figure 6.2.
Vent Termination Restriction Zones - NG / LP.
See also Snorkel Termination vent run restrictions, pg. 12.
Figure 6.4.
Determine the dial notch position appropriate to your vent
configuration as designated in Fig 6.2. Pivot the dial to align the
lock nut with that notch.
TERMINATION
NOT
APPROVED
TERMINATION
NOT
APPROVED
10 ft.
15 ft.
20 ft.
(3.05
(4.57m)
(6.09m)
Lock Nut
A
Pivot
B
Lever
C
D
15 ft.
(4.57 m)
10 ft.
(3.05m)