PRESYS
|
Instruments
2 - Installation
2.1 - Mechanical Installation
The front panel of the DMY - 2035 / 2036 Indicators has 1/8 DIN size
(48 × 96 mm) and the front panel of the DMY - 2011 Indicator has 1/4 DIN size
(96 × 96 mm).
The Indicators are fixed by the rails which press them against the back side of
the panel.
After preparing a 45 × 92 mm cut in the panel for DMY - 2035 / 2036 or a
92 × 92 mm cut for DMY - 2011, remove the rails from the Indicator and slide its rear
through the cut until its front reaches the panel. Place the rails again in the Indicator
from the back of the panel and tighten the screws as shown in figures 3 and 4.
Figure 3 - Dimensional drawing, panel mounting cutout and side view
DMY-2011, DMY-2035 and DMY-2036
for DMY-2035/2036 Indicators
Installation
Page 7