Figure 7.6.
Fuel conversion components and pilot
assembly detail.
8. Reinstall the Burner Plate by engaging the venturi tube
with the Air Shutter. BE CERTAIN THE BURNER IS
LEVEL AND SECURELY SEATED ON THE SUPPORT
LEGS ON THE FIREBOX FLOOR.
9. Replace the variable regulator. Using a Torx T-20
screwdriver, remove the two specialty screws from the
regulator tower on the front of the valve. Note: To help
identify which screws to remove, refer to the new regulator in
the kit. See fig. 7.7.
10. Remove the regulator tower and the rubber diaphragm.
11. Install the new variable regulator tower from the kit. Be sure
that the gasket is properly positioned and tighten screws
securely.
Ignitor
Flame Sensor
Pilot Head
Pilot Orifice
Injector
Remove black
rubber gasket
Variable regulator tower
12 . Apply the identification labels to the stove so that they can be seen
by any person that may be servicing the stove.
• Label "A": Apply to front lip of the valve compartment.
• Label "B": Apply to the Rating Plate.
• Small valve sticker: Apply to valve.
13. Install the accessory panels and burner media as appropri-
ate. See pages 18-21.
14. Apply anti-seize lubricant to the socket head glass frame
screws before reinstalling the glass frame.
15. Apply gas to the system and check for leaks using a soapy
water solution or gas sensor.
16. Follow the System Check instructions on pages 21-22 for initial
start-up and flame picture adjustment.
130102- 1 GF 370 DV MV 2/22
Primary Air
Shutter
Figure 7.7.
Regulator tower removal and replacement