Color Temperature Adjustment - Marantz VP-10S1 User Manual

Marantz vp-10s1: user manual
Hide thumbs Also See for VP-10S1:
Table of Contents

Advertisement

Color Temperature Adjustment

After replacing the lamp or otherwise when the lighting changes,
you can adjust the color temperature using the included color
temperature sensor. In the adjustment procedure, you must first
initialize the sensor itself before adjusting color temperature. It
takes about 10 minutes from when power to the projector is
activated for the lamp's brightness to stabilize. Wait for lamp
brightness to stabilize before adjusting color temperature.
1.
Connect the cable of the color temperature sensor to the
RS-232C port.
2.
Press the MENU button, select "Color Temp. Calibration"
from the menu and press the
message appears on the screen.
Color Temp.Calibration ?
Yes
1
2
3.
Use
and
buttons to select "Yes" and press the
ENTER button. The below message appears on the
screen.
Initialize
Press "ENTER" to start
Before pressing the ENTER button, turn the color
temperature sensor over on its dark side as shown in the
below figure, to prevent outside light from penetrating to
the sensor's receptacle.
Receptacle
38
2
button. The below
No
4.
Press the ENTER button. The below message appears
on the screen for a few seconds as the sensor itself is
being initialized.
Initializing...
5.
Fit the color temperature sensor onto the lens and press
the ENTER button. The lens automatically shifts to the best
position for performing color temperature adjustment. Color
temperature adjustment then starts and the projector's
WARNING and STANDBY indicators begin flashing
simultaneously.
When installed on a flat surface
Attachment for Color
temperature sensor
Attach the color temperature sensor so
that the cable is to the bottom side of the
projector as shown in the figure.
When mounted on a ceiling
Attachment for Color
temperature sensor
Attach the color temperature sensor so that
the cable is to the bottom side of the projector
(now upside-down) as shown in the figure.
6.
When the WARNING and STANDBY indicators go out,
color temperature adjustment is complete. Adjustment
takes about 4 to 5 min. When the color temperature
sensor is detached from the lens, the below message
appears on the screen.
Complete
Press "ENTER" to exit

Advertisement

Table of Contents
loading

Table of Contents