RS232C Control Spec. VP-12S3 Marantz America, Inc. Nov. 22, 2003 Rev. 1.00...
Page 2
RS232C Control Specification for VP-12S3 1. PC Control Interface * RS-232C(Straight Cable) * Baud rate: ........9600 bps * Data length: ........8 bits * Parity: ........... None * Stop bit: ........1 bit * Flow Control: ........ RTS/CTS * Communication procedure:... Full duplex 2.
Page 3
RS232C Control Specification for VP-12S3 Commands, such as Power On Command at the time of notes Standby (Fan operation), return only ACK, when processing is not carried out. For example: When Power On is sent to Projector. Command transmission from PC.
Page 4
RS232C Control Specification for VP-12S3 2.4. Normal Command List Command Character Sample Power On PWR1 "@PWR1",0x0D Power Standby PWR0 "@PWR0",0x0D Component 1 CMP1 "@CMP1",0x0D Component 2 CMP2 "@CMP2",0x0D S-Video "@SVD",0x0D Source Video "@VDO",0x0D "@RGB",0x0D "@AUX",0x0D Theater 1 THE1 "@THE1",0x0D Theater 2 THE2 "@THE2",0x0D...
Page 5
RS232C Control Specification for VP-12S3 Command Character Sample Black Setup 0IRE BSET0 "@BSET0",0x0D Black Setup Black Setup 7.5IRE BSET7 "@BSET7",0x0D Lamp Mode High LMODEH "@LMODEH",0x0D Lamp Mode Lamp Mode Low LMODEL "@LMODEL",0x0D IRIS On IRIS1 "@IRIS1",0x0D IRIS IRIS Off IRIS0 "@IRIS0",0x0D...
Page 6
RS232C Control Specification for VP-12S3 2.5. Request Status Command List Request Status Request Command Answer Sample "@PWR1",0x0D, 0x0a Power "@PWR?",0x0D Standby "@PWR0",0x0D, 0x0a Component 1 "@CMP1",0x0D, 0x0a Component 2 "@CMP2",0x0D, 0x0a S-Video "@SVD",0x0D, 0x0a Source "@SRC?",0x0D Video "@VDO",0x0D, 0x0a "@RGB",0x0D, 0x0a "@AUX",0x0D, 0x0a...
Page 7
RS232C Control Specification for VP-12S3 Request Status Request Command Answer Sample 0IRE "@BSET0",0x0D, 0x0a Black Setup "@BSET?", 0x0D 7.5IRE "@BSET7",0x0D, 0x0a High "LMODEH",0x0D, 0x0a Lamp Mode "@LMODE?", 0x0D "LMODEL",0x0D, 0x0a "IRIS1",0x0D, 0x0a IRIS "@IRIS?", 0x0D "IRIS0",0x0D, 0x0a Auto Power Auto "@APO1",0x0D, 0x0a...
Page 8
RS232C Control Specification for VP-12S3 2.6. Special Command List Request Status Request Command Answer Sample Order Number "@ORDER", 0x0D 07AV "@07AV",0x0D, 0x0a Main u-com Build "@BUILD_MAIN?", Num. 0x0D Build 0025 "0025",0x0D, 0x0a Sub u-com Build Num. "@BUILD SUB?", 0x0D Build 0025 "0025",0x0D, 0x0a...
Page 9
RS232C Control Specification for VP-12S3 It is asked for frequency by the following formulas from the return value of V Sync. In addition, since return value is Hex, be careful. frequency × return value × Build Number expresses the thing of a sub microcomputer.