Automatic Retraction Of The Blind; Push-Button Mode Or Maintained Mode - Nice Elero ExitSafe 28 388.0001 Manual

Table of Contents

Advertisement

5.4

Automatic retraction of the blind

When automatic retraction of the blind is activated,
ExitSafe will control the UP drive if the charge level of
the battery pack has dropped to such an extent that only
one complete movement of the drive can be ensured.
Automatic retraction of the blind can be set with DIP
switch 3.
DIP switch 3 OFF
No automatic retraction of the blind. An acoustic signal is
emitted only in the case of a low battery pack charge level.
DIP switch 3 ON
Automatic retraction of the blind activated. When the battery
pack is at a low charge level, a warning signal will sound and
the drive will be controlled UP.
5.5

Push-button mode or maintained mode

ExitSafe can be operated either in push-button mode or
with maintained mode. The duration of the maintained
mode is approx. 180 s and can be terminated earlier via
a short input pulse.
DIP switch 4 OFF
Push-button mode. The drive is controlled only as long as
an input is operated. This is helpful if a connected command
initiator takes over maintained mode.
DIP switch 4 ON & DIP switch 5 OFF
Immediate maintained mode. The drive control remains
active after the input signal has dropped.
elero GmbH
EN | 23

Advertisement

Table of Contents
loading

Table of Contents