Function position
DIP
OFF
1
Individual control has
priority over master
control
2
A warning signal will
sound after two years
of operation or
500 charging cycles
of the battery pack.
3
The drive will not
be automatically
controlled UP at a
low battery pack
level.
4
Push-button mode
5
Maintained mode is
activated immediately
6
Normally open
contact at the signal
input ▲
Table 4: Settings overview
4.6

Connection and installation

WARNING
Risk of injury, damage to the ExitSafe and
damage to the area surrounding the ExitSafe
due to improper electrical connections.
18 | EN
Function position ON
Master control has priority over
individual control
No warning signal will sound
after two years of operation
or 500 charging cycles of the
battery pack.
The drive will be automatically
controlled UP at a low battery
pack level.
Maintained mode
Maintained mode is activated
after a delay
Normally closed contact at the
signal input ▲ (wire breakage
detection).
elero GmbH
Off | On