Wire breakage recognition
Figure 2: Wire breakage detection
4
Technical data
4.1
Electrical data
Electrical data
Power supply input
Max. power consumption for input
Output voltage motor terminals
Rated current motor terminals
Max. current motor terminals
Rated current command initiator
Alarm / smoke detector: i
nput with wire break detection
Coding:
DIP 6: on
DIP 1: on
elero GmbH
230 V AC, 50 Hz
5.5 W
8.4 to 12 V DC
4 A
22 A, 10 ms
1.2 mA
EN | 13