4.2.26.5 Motor Plate Removal
1. Remove 2 motor connectors from the Motor Plate and 3 screws securing
the Plate.
Figure 4-70. Motor Plate Removal
Disassembly and Assembly
4.2.26.6 Reverse Motor Removal
1. Remove 3 screw securing the Motor Plate.
2. Remove the harness from 3 harness saddles.
3. Remove 2 screws securing the Switch Back Motor.
Figure 4-71.
4.2.26.7 Duplex Paper Load Motor Removal
1. Remove 3 screw securing the Motor Plate.
2. Remove the harness from 3 harness saddles.
3. Remove 2 screws securing the Duplex Paper Load Motor. (See Figure
4-71."Reverse Motor / Duplex Paper Load Motor" on page -178.)
Disassembling Procedure
Reverse Motor / Duplex Paper Load Motor
Revision E