EPSON AcuLaser C2000 / AcuLaser C1000
4.2.10 Fusing Pressure Motor Removal
1. Remove the PU1 Support Board. (See "PU1 Support Plate Removal" on
page -154.)
2. Remove the harnesses from the connectors on the Fusing Pressure Motor.
3. Remove 4 screws securing the Fusing Pressure Motor Support Board to
the printer frame and the grounding screw.
4. Remove 2 screws securing the Fusing Pressure Motor, and remove the
Fusing Pressure Motor.
Figure 4-27. Fusing Pressure Motor Removal
Disassembly and Assembly
4.2.11 Fan Motor Removal
4.2.11.1 Power Supply Fan Motor Removal
1. Remove the Rear Controller Cover. (See "Rear Controller Cover Removal"
on page -145.)
2. Remove the Rear Right Cover. (See "Rear Right Cover Removal" on
page -146.)
3. Free the harness from 5 harness clamps.
4. Disconnect the power supply fan motor harness and remove 2 long screws
securing the Power Supply Fan Motor, and remove the Power Supply Fan
Motor.
Figure 4-28. Power Supply Cooling Fan Motor Removal
Disassembling Procedure
Revision E
155