1.10 Differences between AcuLaser C2000 and AcuLaser C1000

AcuLaser C1000 is different from AcuLaser C2000 in the following points:
Features that are not supported
Type-B interfaces are not supported except Leo2.1.
The supported protocols are TCP/IP and AppleTalk.
Neither PS options nor HDD is supported.
Can not be used in the DOS environment (emulation mode is unavailable).
The printer itself does not retain the MIB information.
The manual feed mode is not supported.
Usability
Does not have the function to permit, in the case of the Toner Out error
occurrence, pressing the Continue switch to continue printing.
No error status is identified unless the EPSON Status Monitor is used.
Jobs sent via a network can not be canceled (the Job MIB is not
supported).
The warning of consumable will not be cleared without actual replacement
of the consumable.
Operation
The paper out error will occur only after printing start even if no paper
source holds any paper at turning on of power to the printer.
The Paper Type setting is not supported, but the MP Tray can be excluded
from auto selection.
When "Avoid Error = On" is selected, "Print Failure" warning will occur
instead of the error.
"Can't Print Duplex" warning will occur instead of the error when duplex
printing is impossible.
Product Descriptions
Differences between AcuLaser C2000 and AcuLaser C1000
The printer prints nothing when "Mem Overflow" or "Duplex Mem Overflow"
occurs.
Others
The present remainder of the life of the fuser unit and the transfer belt can
not be known (engine status sheet is not available).
DIAG commands are not supported.
Screen, LUT can not be changed by an optional DIMM. Screen, LUT can
not be changed by an optional DIMM.
The AIDC value is not known (It is not described on the Status Sheet).
The mechanical controller firmware can not be updated.
Revision E