DMX-512 CONNECTION/CONNECTION BETWEEN FIXTURES

The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and
output. The sockets are wired in parallel.
Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-
plugs and connectors in order to connect the controller with the fixture or one
fixture with another.

OCCUPATION OF THE XLR-CONNECTION

DMX – output
Connettore XLR (vista posteriore):
If you are using the standard DMX controllers, you can connect the DMX output of
the controller directly with the DMX input of the first fixture in the DMX chain. If
you wish to connect DMX controllers with other XLR outputs ,you need to use
adapter-cables.

BUILDING A SERIAL DMX CHAIN

Connect the DMX output of the first fixture in the DMX chain with the DMX input of
the next fixture. Always connect one
output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX cable has to be terminated with a terminator.
Solder a 120 Ohm resistor between Signal (–)and Signal (+) into a XLR plug and
plug it in the DMX output of the last fixture.

DISPLAY INFORMATION

FIXTURE TEMPERATURES - - - - Select this submenu to read the temperatures of the
fixture:
CURRENT - Select this function to read the current temperatures of the fixture
inside (Board Temp., Ambient Temp., Near Lamp Temp.)
DMX- input
Connettore XLR (vista posteriore):
1: Shield
2: Signal (-)
3: Signal (+)
4: Not connected
5: Not connected